TA D-LOGG Скачать руководство пользователя страница 6

 

USB driver 

The USB driver is required for USB communication between the PC and D-LOGG and it cre-
ates a virtual COM port on the PC for this purpose. 
 
The driver must be installed on the PC for this (see 

"

Installation

"

) and is automatically load-

ed when a D-LOGG is connected to the PC. 
The required drivers can be installed from the homepage 

http://www.ta.co.at

 or also via Win-

dows Update.

 

 

 

Installation 

When a D-LOGG is connected to the PC with a USB cable, the PC automatically recognises 
a  new  hardware  component  and  automatically  starts  the  "Hardware-Assistant"  (Hardware 
Wizard) if a driver has not yet been installed for this device. 

If  an  Internet  connection  is  available, Windows  connects  automatically  to  the Windows  Up-
date website to install a suitable driver. In this case no further steps are necessary. 

If an Internet connection is not available, or no suitable driver has been found or if Windows 
is configured to prevent the automatic installation of drivers, the required drivers can be man-
ually installed. 

If the Wizard does not start automatically, the installation can also be manually started. When 
the device is connected to the PC but the driver has not been installed, it is displayed in the 
Windows 

device Manager)

 with an exclamation mark in one of the <

other devices

>, <P

orts 

(COM  and  LPT)

>  or  <

USB  Controller

>  lists.  The  driver  installation  can  be  manually  started 

from here. 

For more detailed information please see the USB-drivers manual under 

http://www.ta.co.at

 

Содержание D-LOGG

Страница 1: ...D LOGG Version 2 9 EN Manual version 2 Data converter Operation Winsol Memory Manager en...

Страница 2: ...2...

Страница 3: ...asic settings 8 Setup dialogue 9 Current measured values 13 Customer mode 14 Add new customer 14 Open customer 14 Manage customer 14 Recording of measured values from a customer system 15 Read out log...

Страница 4: ...no power is present This means that a power loss will result in a maximum loss of the last hour of data Data line Every UVR controller has a data line output DL with the EEG30 TFM66 D0 that together...

Страница 5: ...to provide power for the data converter from the PC For this reason the slide switch may only be set to the USB position when no connection to a controller exists For communication between the PC and...

Страница 6: ...an Internet connection is available Windows connects automatically to the Windows Up date website to install a suitable driver In this case no further steps are necessary If an Internet connection is...

Страница 7: ...configure the virtual COM port in the Windows Device Manager Windows XP classic view Start Settings Control Panel System Hardware Device Manager Ports COM and LPT Windows Vista classic view Start Sett...

Страница 8: ...enu Optionen Sprache Op tions Language and click on the desired language Winsol must be restarted for the lan guage choice to come into effect Basic settings The Winsol data path can be changed in the...

Страница 9: ...h forward to the next setup window while Cancel is used to cancel setup without changing the logger configuration 1 Window Data logger connection Summary Selection of the data logger D LOGG Selection...

Страница 10: ...is not known Find logger is used to search all the COM interfaces of the computer for connected loggers The COM port and type of the logger found are displayed Apply is used to set the high lighted l...

Страница 11: ...ed is given under Number The logged devices are then selected by double clicking in the respective fields An ESR31 controller is selected as an ESR21 UVR63 and UVR63H controllers are selected as UVR61...

Страница 12: ...number of controllers to be recorded Max number of points in time Data logging using the DL bus Controller type With 1xDL With 2xDL UVR1611 UVR61 3 UVR63 UVR63H 8000 4000 ESR21 ESR31 16000 8000 All o...

Страница 13: ...for testing the Con troller data logger data connection Each data record device is displayed in its own view The selection is made using a selec tion box in the top part of the window The point in tim...

Страница 14: ...h customer in which the cor responding configurations and log files are saved The directory Info sol in the Winsol data path contains all these customer folders There is also an option of trans ferrin...

Страница 15: ...ng to the selected save criterion 7 When disconnecting the data logger from the controller date and time must be not ed because Winsol needs these so that when reading data in the correct time can be...

Страница 16: ...e 2 The logger has been disconnected from the device Winsol now requests entry of the point in time at which the disconnection occurred 3 Interruption of data recording If logging has been interrupted...

Страница 17: ...r csv Existing files are overwrit ten Shut down computer This option is also possible Here as the PC boots up the data are automatically read in incl possible csv conversion and then the PC shutdown a...

Страница 18: ...og and 16 digital values from all the logged values can be displayed simultaneously The menu option Manage profiles is used to select the values to be displayed and the colour of the curves Moreover i...

Страница 19: ...display window per key press Move the mouse with the right mouse button de pressed X axis zooming Navigation Keyboard Mouse X axis zooming z The fixed point is the position of the cursor if activated...

Страница 20: ...of the diagram Scroll back pressed Ctrl key Fixed point is the position of the mouse pointer Zooming in X and Y axes simultaneously Navigation Keyboard Mouse Zoom in X and Y axis Zoom window with dep...

Страница 21: ...forward Ctrl min 1 24 of the display pane step back Ctrl 1 day step forward Toolbar 1 day step back Toolbar 1 month step forward Ctrl Toolbar 1 month step back Ctrl Toolbar Start day Pos1 End day End...

Страница 22: ...lled Example Display of non logged times If there is less than 1 whole day between the logged data records then the last measured point is linked to the first measured point for a particular sensor by...

Страница 23: ...the day displayed Navigation Navigation forwards or backwards in the data recording by a day or month Here only days are displayed on which measured values have been recorded I e days without any data...

Страница 24: ...ted for various system areas and a separate diagram title specified Export In this menu the log files can be converted into csv file format for further processing with any spreadsheet program In this...

Страница 25: ...the settings which are necessary for correct communi cation between the PC and the D LOGG Save the set interface parameters Using the command TEST COM it is possible to carry out an automatic search o...

Страница 26: ...update It is advisable to read out any logged data before updating the operating system All program elements required for the system update are stored in a protected storage area boot sector that cann...

Страница 27: ...s data link On controller UVR16x2 data output must be enabled in DL settings in the menu DL bus 4 If several controllers are recorded using the data logger check the data connections individually to l...

Страница 28: ...time the time or the point in time at which the data logger was disconnected from the controller is taken from the PC so that the time can be allocated to the recorded data The csv files are not disp...

Страница 29: ...1 General requirements EN 61000 6 3 2007 A1 2011 AC2012 Electromagnetic compatibility EMC Part 6 3 Generic standards Emission standard for residential commercial and light industrial envi ronments EN...

Страница 30: ......

Страница 31: ......

Страница 32: ...and installation instructions or incorrect maintenance 4 The guarantee claim will expire if repairs or actions are carried out by persons who are not au thorised to do so or have not been so authoris...

Отзывы: