Winsol
11
2. Window: Data recording
Summary:
Reading out
of the configuration
stored in the logger
Specification of the
Source
and
number of data links
Specification of the device types,
Selection of the saving criterion
Overwriting
of the configuration in
the logger
The changed settings are
only saved and trans-
ferred as a configuration
to the logger if this button is clicked.
Source: DL (data link)
The parameters contained in the data records (devices) are firmly specified in this process.
Up to 2 data records (devices) can be recorded.
The number of devices to be logged is given under "
Number
".
The logged devices are then selected by double clicking in the respective fields. An ESR31
controller is selected as an "ESR21", UVR63 and UVR63H controllers are selected as
"UVR61-3".
If under Output 14 of the UVR1611 "
NETW.IP.=>DL.:
" is set to "
yes
", the measured values
from the network inputs are output as a
2nd device
on the DL-Bus. If "
NETW.IP.=>DL.:
" is
switched from "
yes
" to "
no
", the data logger must be briefly switched off (no power supply)
so that it can reinitialise itself.
Saving criterion
The saving criterion is used to specify
when the data logger is to save a point-
in-time with all captured measured val-
ues.
Two criteria are
optionally
available for
data logging.
Time interval
Entry of a time interval between 20 seconds and 40 minutes is possible.