background image

Thoma •  Tel./Fax: +48 95 741 11 62 • [email protected] • www.t4w.eu

3

Operation Manual

TW-2B

Technical specifications

1. 

Basic specifications of the device:

measurement on steel, galvanized steel and aluminium;

• 

measurement resolution: 10µm;

• 

measurement range: from 0µm to 1100µm;

• 

measurement memory (also after turning the device off): 100 units;

• 

zeroing function;

• 

LCD backlight;

• 

intuitive operation with 6-positions menu;

• 

automatic shut-off after longer idleness;

• 

measuring sensor diameter: 15 mm;

• 

powered by 9V alkaline battery (e.g. 6LR61) or corresponding accu;

• 

power consumption: ~50 mA..

• 

Getting started

2. 

Coating thickness gauge TW-2B is designed to measure the thickness of a steel, galvanized 
steel or aluminium sheet paint coating. The measurement resolution equals 10µm. The device 
has a LCD backlight which makes measuring in places with insufficient light (e.g. garage) much 
easier.

Before You start to use the device, please place a new alkaline battery or a fully charged accu 
in the back side of the device’s housing. In order to do it please take off the battery flap and 
place correctly the battery or accu by connecting it to the clips on the cable.Before You start to 
take measurements, please place a new alkaline battery or a fully charged accu in the back side 
of the device’s housing. In order to do it please take off the battery flap and place correctly the 
battery or accu by connecting it to the clips on the cable.

WARNING! 

T

he

 

devIce

 

Is

 

pReseT

 

To

 

GAlvANIzed

 

sTeel

 

ANd

 

AlumINIum

  (z

N

/A

l

)!  s

hould

 

The

 

meAsuRemeNT

 

be

 

TAkeN

 

oN

 

oldeR

 

cARs

 

WITh

 

NoN

-

GAlvANIzed

 

sTeel

 

bodyWoRk

The

 „s

Teel

” 

opTIoN

 

shAll

 

be

 

choseN

Zeroing (calibration)

Before You start to take measurements, please check whether the gauge is calibrated. To do it 
properly, please select the 

Zero

 function from the main menu and put the sensor against the 

green side of the calibration sheet. If the display shows a 0 +/-10µm value, it means that the 

Содержание TW-2B

Страница 1: ...Thoma Tel Fax 48 95 741 11 62 info t4w eu www t4w eu Coating Thickness Gauge TW 2B Operation Manual art nr 5924 7 ...

Страница 2: ...peration Manual TW 2B Table of contents 1 Technical specifications 3 2 Getting started 3 3 Gauge manual 4 Guarantee TW 2B 8 The price of this product includes the recycling fee of 0 10 PLN Before You start to use the device please read this operation manual ...

Страница 3: ...age much easier Before You start to use the device please place a new alkaline battery or a fully charged accu in the back side of the device s housing In order to do it please take off the battery flap and place correctly the battery or accu by connecting it to the clips on the cable Before You start to take measurements please place a new alkaline battery or a fully charged accu in the back side...

Страница 4: ...normal batteries provide unsufficient power 2 Instead of a alkaline battery You can use a compatible fully charged accu 3 If the device seems to work improperly it can be caused by an empty battery or accu To take a measurement please put the device s sensor against the examined surface The sensor should adhere as flat as possible The examined surface should be clean and smooth otherwise the measu...

Страница 5: ... select a function please press the OK MENU button Measure function Measur After You select this function the display will show Measur in the first line and um in the second The gauge is ready to take measurement After You put the sensor against the body of the car the result of the measurement will be shown in the second line To store the result please press the OK MENU button when taking the mea...

Страница 6: ...eel Fe You can switch between the sheet materials with the FUNKTION button to accept the selection press the OK MENU button Delete function Delete Choose this function to delete all measurement values stored in the device s EEPROM internal memory After deleting the stored results the device returns to the main menu automatically Zeroing function Zero Use this function before You start to take meas...

Страница 7: ...pears in the second line of the display otherwise the gauge will decalibrate WARNING While zeroing the calibration sheet should be placed on a flat stable non metalic surface e g do not place the sheet on the bodywork Also please avoid holding the sheet in Your hands as this may affect the operation Please note that zeroing is worth to be made when the measurement conditions are changing e g the t...

Страница 8: ... be shipped to the Producer it happens on the shipper s responsibility and cost 8 The device will be not accepted by the Service if pt 6 is not kept if the defect is of no workmanship or 9 material nature if the warranty card is not filled out or the device is delivered with broken seal This guarantee shall not apply to damage caused through fire accident misuse incorrect adjustment or 10 repair i...

Отзывы: