BW/BWS/VW/CW/NTW/NSW weighing indicator operation manual REV: C1, March 2015 BW/BWS/VW/CW/NTW/NSW weighing indicator operation manual
Press the
TARE
key to tare the scale. The weight that was
displayed is stored as the tare value and that value is subtracted from
the display, leaving zero on the display. The "NET" indicator will be on.
As product is added only the weight of the product will be shown. The
scale could be tared a second time if another type of product was to be
added to the first one. Again only the weight that is added after taring
will be displayed.
When the container is removed a negative value will be shown. If
the scale was tared just before removing the container this value is the
gross weight of the container plus all product that was removed. The
zero indicator will also be on because the platform is back to the same
condition it was when the
ZERO
key was last pressed.
3.3 Weighing a sample
To determine the weight of a sample first tare the empty container
then place the sample in the container. the display will show the weight
and the units of weight currently in use.
4. CHECK-WEIGHING
4.1 About check-weighing
Check-weighing is a procedure to cause an alarm to sound when the
weight on the scale meets or exceeds values stored in memory. The
memory holds values for a high limit and a low limit.
Check mode OK:
When check range, the display will show OK and the beeper will
sound when the weight is between the limits.
Check mode NG:
When check range, the display will show OK and the beeper will
sound when the weight is out of the limits.
4.2 Set limits
Press
G/N
and
key together,
it will display “
set h
”, use
TARE
-3-
key to select “
SET H
” or “
SET L
”, press
ZERO
key to enter, use
M+
and
MR
key to move active digit, use
TARE
key to change value, use
key to clear value. After you enter the value, press
ZERO
key to sure,
press
G/N
key to escape.
4.3 Set check weighing mode
Press
G/N
and
key together,
it will display “
set h
”, use
TARE
key to select
beep
, press
ZERO
key to enter, press
TARE
key to select
ok
(check mode OK),
ng
(check mode NG),
no
(no beep), press
ZERO
key to sure, press
G/N
key to escape.
4.4 NOTE
Checkweighing function only available when weight more than 20d.
To disable the Check-Weighing function enter zero into both limits
by pressing the
key when the current limits are shown then
pressing
ZERO
to store the zero values.
5. ACCUMULATED TOTAL
5.1 Note
The scale can be set to accumulate manually by pressing the
M+
key. See the PARAMETERS Section for details of selecting the method
using function "
P2 com
".
Please note before every accumulate operate, scale need return to
zero, and only press
M+
key when stable, when weight less than 20d,
accumulate operate will be invalid.
5.2 Accumulate operate
The weight displayed will be stored in memory when the
M+
key is
pressed and the weight is stable.
The display will show "
ACC 1
" and then the total in memory for 2
seconds before returning to normal. (after do accumulate operate,
“M+”
indicator will turn on) If the optional RS-232 interface is installed the
weight will be output to a printer or PC.
-4-
Содержание bw series
Страница 1: ...BW BWS VW CW NTW NSW Weighing Indicator...