Press  the 

TARE

  key  to  tare  the  scale.  The  weight  that  was 

displayed  is  stored  as  the  tare  value  and  that  value  is  subtracted  from 

the display, leaving zero on the display. The "NET" indicator will be on. 

As  product  is added  only  the  weight  of  the  product  will  be  shown.  The 

scale could be tared a second time if another type of product was to be 

added  to  the  first  one.  Again  only  the  weight  that  is  added  after  taring 

will be displayed. 

When  the  container  is  removed  a  negative  value  will  be  shown.  If 

the scale was tared just before removing the container this value is the 

gross  weight  of  the  container  plus  all  product  that  was  removed.  The 

zero indicator will also be on because the platform is back to the same 

condition it was when the 

ZERO

 key was last pressed. 

3.3 Weighing a sample 

To determine the weight of a sample first tare the empty container 

then place the sample in the container.    the display will show the weight 

and the units of weight currently in use.         

 

4. CHECK-WEIGHING 

4.1 About check-weighing 

Check-weighing is a procedure to cause an alarm to sound when the 

weight  on  the  scale  meets  or  exceeds  values  stored  in  memory.    The 

memory holds values for a high limit and a low limit.   

Check mode OK:   

When  check  range,  the  display  will  show  OK  and  the  beeper  will 

sound when the weight is between the limits.     

Check mode NG: 

When  check  range,  the  display  will  show  OK  and  the  beeper  will 

sound when the weight is out of the limits.     

4.2 Set limits 

Press 

G/N

 and 

PRINT

 key together, 

it will display “

set h

”, use 

TARE

   

-3- 

key to select “

SET H

” or “

SET L

”, press 

ZERO

 key to enter, use 

M+

 and 

MR

 key to move active digit, use 

TARE

 key to change value, use 

Print

 

key to clear value. After you enter the value, press 

ZERO

 key to sure, 

press 

G/N

 key to escape. 

4.3 Set check weighing mode 

Press 

G/N

 and 

print

 key together, 

it will display “

set h

”, use 

TARE

 

key to select 

beep

, press 

ZERO

 key to enter, press 

TARE

 key to select 

ok

(check mode OK), 

ng 

(check mode NG), 

no

(no beep), press 

ZERO

 

key to sure, press 

G/N

 key to escape. 

4.4 NOTE 

Checkweighing function only available when weight more than 20d. 

To  disable  the  Check-Weighing  function  enter  zero  into  both  limits 

by  pressing  the 

PRINT

  key  when  the  current  limits  are  shown  then 

pressing 

ZERO

 to store the zero values. 

 

5. ACCUMULATED TOTAL 

5.1 Note 

The  scale  can  be  set  to  accumulate  manually  by  pressing  the 

M+

 

key. See the PARAMETERS Section for details of selecting the method 

using function "

P2 com

".     

Please note before every accumulate operate, scale need return to 

zero, and only press 

M+

 key when stable, when weight less than 20d, 

accumulate operate will be invalid. 

5.2 Accumulate operate 

The weight displayed will be stored in memory when the 

M+

 key is 

pressed and the weight is stable. 

The display will show "

ACC  1

" and then the total in memory for 2 

seconds before returning to normal. (after do accumulate operate, 

“M+” 

indicator  will  turn  on)  If  the  optional  RS-232  interface  is  installed  the 

weight will be output to a printer or PC. 