BW/BWS/VW/CW/NTW/NSW weighing indicator operation manual REV: C1, March 2015 BW/BWS/VW/CW/NTW/NSW weighing indicator operation manual
Remove the weight, allowing the scale to return to zero and put a
second weight on. Press the
M+
key, the display will show "
ACC 2
"
and then the new total.
Continue until all weights have been added.
5.3 memory recall
To view the totals in memory press
MR
key.
5.4 memory clear
To clear the memory, just press
M+
and
MR
together
5.5 automatically accumulate
Press Print key during selfchecking, enter setting mode, press Tare
key until display show
P2COM
, press
ZERO
key to enter, press
TARE
key to select
“
mode
”, press
ZERO
key to sure, display will show current
RS-232 mode, press TARE key to select
Auto
. After you set, AUTO
indicator on.
Press weight on platform, after stable, you will hear beep on twice,
you can add or remote weight now, scale will beep on again after stable,
at last, remove all weight on platform, the last weight value will store in
memory
6. PARTS COUNTING
Hold
MR
key
2 seconds
to enter parts counting mode, display
show
“
P 10
”, press
TARE
key to select sample quantity
(10/20/50/100/200), put the sample goods on platform (the quantity
same as shown on display), press
ZERO
key to sure, display will show
“-----“, then show current quantity. Sampling finished.
After sampling, add goods on the platform, display will show it
’s
quantity.
In counting mode, you can pres
MR
key to normal weighing mode.
-5-
M+
or
Accumulate key, store current weight in memory.
In setting mode, this key used to move active digits left.
Press
M+
and
MR
key for MC (memory clear)
or
To print the results to a PC or printer using the RS-232 interface.
Press
during selfchecking will enter setting mode.
G/N
or
weighing unit shift.
Secondary function (ESC) , is to return to normal operation when
the scale is in a parameter setting mode.
Hold
G/N
key for weighing unit shift.
Press
G/N
and
key together for setting check Weighing limit.
3. BASIC OPERATION
3.1 Zeroing The Display
You can press the
ZERO
key at any time to set the zero point from
which all other weighing and counting is measured, within 4% of power
up zero. This will usually only be necessary when the platform is empty.
When the zero point is obtained the display will show the indicator for
zero.
The scale has an automatic rezeroing function to account for minor
drifting or accumulation of material on the platform. However you may
need to press the
ZERO
key to rezero the scale if small amounts of
weight are shown when the platform is empty.
3.2 Taring
Zero the scale by pressing the
ZERO
key if necessary. The zero
indicator will be on.
Place a container on the platform, a value for its weight will be
displayed.
-2-
Содержание bw series
Страница 1: ...BW BWS VW CW NTW NSW Weighing Indicator...