Front panel controls
1
1
1
1
Main switch
The main switch is used to select the mode of operation
(OFF, STBY, HEAT, HV) as well as the listening source.
The switch can be rotated manually in either direction. If
the remote control handset is used, the motorised switch
moves automatically to the selected position.
The function of the various switch positions is as follows:
OFF
The amplifier is switched off.
In this switch position the unit does not respond to
commands from the remote control handset. The unit
must be switched on manually by rotating the main
switch.
STBY
(Standby mode)
In Standby mode the amplifier is also switched off; power
is only supplied to the remote control receiver. However,
this means that the
V10
can now be switched on from the
Standby setting using the remote control handset.
HEAT
Moving the switch to the HEAT setting switches on the
valve heating, but the amplifier itself remains switched
off. The HEAT setting is designed to avoid the valves
cooling off between periods of listening (intervals of
5 minutes .. 2 hours).
In the HEAT setting the high voltage is still switched off;
current consumption is reduced, and the valves are not
under load. The operating hours counter (see section
'
BIAS / Operating hours display
'
) does not run in this
mode.
HV
Moving the switch to the HV setting switches on valve
heating and high voltage. The idle current of the valves is
reduced to a minimum.
This setting is recommended for brief breaks between
listening sessions (< 5 minutes).
Operating positions
TUNER / DISC / AUX / AUX/PH / RECORDER
Moving the main switch to any of these positions
switches on the
V10
completely, rendering it ready to
use; you can now listen to the selected source. At the
same time the signal supplied by the selected source is
also present at the recorder outputs, and can be
recorded on a machine capable of this function.
Switching on the V10
The
V10
can be turned on by moving the main switch
from any setting (i. e. including the OFF or STBY
position) directly to one of the operating positions.
The micro-processor control system ensures that the
valves are always heated gently to the optimum level,
and that the high voltage is not switched off prematurely.
The smooth, processor-controlled warming-up process of
the
V10
avoids damage to the valves and extends their
useful life. If the
V10
is switched on from cold, it takes
about one minute for the valves to heat up fully.
During the initial heating phase the delay display on the
screen flashes, and the operating hours display appears.
When the correct operating temperature is reached and
the high voltage is switched on, the high voltage symbol
appears on the screen and the operating hours display
disappears. The amplifier is now ready for use, the
loudspeaker outputs are active, and you can start
listening.
The main switch:
The main switch is not a mains isolation switch; even in
the OFF position electrical current is supplied to a few
parts of the circuit. However, the current drain in the
OFF position is reduced to less than 1 Watt.
There is an additional mechanical mains switch
located on the back panel of the amplifier,
and this
disconnects the device completely from the mains
supply.
This switch must be in the ON position if
you wish to use the amplifier.
It is not normally
necessary to switch the unit off using the rear mains
switch, and this is only recommended if you are certain
to be away from home for a protracted period (e. g. a
holiday).
The three positions at the bottom marked
HV
have the
same function as the upper HV position.
26