28
Notes on Energy Saving
General
information
The
AMP 8
satisfies the requirements of the latest directives concerning
energy-saving measures (EuP directive). The modern design of the
mains power supply makes an important contribution to this.
The internal micro-processor constantly ensures that sub-assemblies
which are not currently required are automatically switched off. The
micro-processor itself operates in stand-by mode at a relatively low clock
speed.
In stand-by mode the current drain of the
AMP 8
is less than 0.2 Watt.
If you intend not to use the amplifier for a long period, it should be
disconnected from the mains socket, i.e. the mains plug should be
withdrawn from the wall socket or switch off the main switch.
Automatic
power-on
The
AMP 8
features an automatic power-on circuit. If the amplifier
detects a music signal at one of its inputs, it automatically switches itself
on. If no music signal is detected for a period longer than 20 minutes, the
AMP 8
automatically switches to stand-by mode.
Trouble shooting
Many problems have a simple cause and a correspondingly simple solution. The following
section describes a few difficulties you may encounter, and the measures you need to take to
cure them. If you find it impossible to solve a problem with the help of these notes please
disconnect the unit from the mains and ask your authorised
specialist dealer for advice.
Machine does not switch
on.
Cause 1:
Mains lead not plugged in correctly.
Remedy:
Check connection, push connector in firmly.
Cause 2:
Mains switch on the back panel not switched on.
Remedy:
Switch the mains switch on
.
Combined with DAC 8
Machine switch on with a
certain time delay
Cause:
CTRL-cable between
AMP 8
and
DAC 8
is not properly
connected.
Remedy:
Please check and properly install the control-cable
Loud humming noise from
the loudspeakers
Cause:
Poor contact between the RCA or XLR plugs and sockets, or a
faulty cable.
Remedy:
Please check all connections and cables thoroughly.
Содержание AMP 8
Страница 1: ...Bestell Nr Order no 9103 0480 DE UK Betriebsanleitung User manual AMP 8 ...
Страница 2: ...2 ...
Страница 3: ...3 Seite Page Deutsch 4 English 17 ...
Страница 16: ...16 ...
Страница 17: ...17 English ...
Страница 36: ... elektroakustik GmbH Co KG Herford Deutschland Germany Allemagne ...