The ferrite ring on the 

POWER BAR

 cable is movable, i.e. you 

can re-position it to deal with the frequency spectrum which is 
causing you problems. If interference occurs, adjust the position 
of the ferrite ring until the optimum

 

 
 

 

 

Interference generated 
by other system 
components 
 

 

It  is  not  only  external  equipment  which  generates  interference; 
the  individual  components  of  a  Hi-Fi  system  -  especially  digital 
machines  -  can  also  cause  problems.  The  design  of  the 

 

mains  filter  system  prevents  such  interference  reaching  other 
units  via  the  mains  wiring  system.  This  is  achieved  by  de-
coupling  the  source  device  sockets  from  each  other  using 
separate  shield  current  blocking  filters.  Additionally  all  the 
sockets are wired in a star-type cabling from a central connecting 
point. 

 
 

 

 

Polarity indicator 
 

 

The  polarity  of  the  mains  connector  can  make  a  difference  with 
many  high-quality  Hi-Fi  components,  and  it  is  important  to 
establish this correctly. The mains connector polarity can have a 
significant  influence  on  the  quality  of  reproduced  sound, 
depending  on  the  winding  technology  employed  for  the  mains 
transformer  and  the  design  of  the  mains  power  supply  section. 
The 

POWER  BAR

  includes  a  visual  polarity  indicator  which 

enables  you  to  check  that  polarity  is  correct.  The  mains  plug 
attached to the 

POWER BAR

 should be connected in such a way 

that  the  indicator  LED  does  not  glow.  If  the  polarity  is  set  up  in 
this way, the marked terminal of each mains supply socket is the 
phase line, and this should be connected to the correspondingly 
marked terminal of the Hi-Fi unit connected to that socket. If you 
use  the 

 

POWER  LINE

,  all  you  have  to  do  is  connect  the 

marked terminal of the safety mains plug to the marked terminal 
of  the 

POWER  BAR

,  and  all  the 

  units  connected  to  the 

distribution  panel  will  have  correct  polarity  automatically,  since 
the Euro mains connectors which we use are polarised, i.e. they 
can only be connected one way round. 

 
 

 

 

Voltage surge 
protection 

 

 

Modern  Hi-Fi  devices  are  very  sensitive  to  voltage  peaks  and 
surges  which  can  occur  in  the  mains  power  network  due  to  a 
lightning  strike  or  other  event.  The 

POWER  BAR

  mains 

distribution  panel  includes  an  integral  surge  protection  circuit 
designed  to  widen  the  safety  margin  for  the  components 
connected to  the  panel.  This circuit  can suppress currents  of  up 
to  10000  Amps  and  more,  and  thereby  prevents  almost  all 
dangerous excess voltage peaks reaching the devices connected 
to  the  system.  If  other  electrical  equipment  in  your  house  is 
damaged by a lightning strike, please check the surge protection 
circuit of the 

POWER BAR

. In case of failure the polarity indicator 

LED  lights  up  red.  Please  note  that,  like  a  standard  electrical 
fuse, this circuit may be destroyed by a serious surge in voltage, 
so it is essential to ask your specialist 

 dealer to If you fail to 

do this the protective effect of the system may be lost. 

Содержание POWER BAR 2+3

Страница 1: ...Bestell Nr Order no 9103 0492 DE UK Gebrauchsanweisung Operating instructions POWER BAR 2 3 POWER BAR 2 5...

Страница 2: ...2...

Страница 3: ...ist die Steckerleiste mit einem berspannungsschutz ausgestattet der Spannungsspitzen vermindert wie sie h ufig bei Gewittern oder Schaltvorg ngen auftreten und somit die angeschlossene hochsensible Hi...

Страница 4: ...r Netzversorgung wirken wie Antennen Zudem sind an das elektrische Versorgungsnetz in der Regel eine Reihe von stark st renden Ger ten wie Computer Schalt Steueranlagen und Maschinen angeschlossen die...

Страница 5: ...Polung ist der mit einem Punkt gekennzeichnete Pol der Netzsteckdosen der Phasenanschluss er sollte mit dem entsprechend gekennzeichneten Pol des jeweiligen HiFi Ger tes verbunden werden Bei Verwendun...

Страница 6: ...zt z B beim Transport so ist mit der Inbetriebnahme zu warten bis sich die POWER BAR auf Raumtemperatur aufgew rmt hat und das Kondenswasser restlos verdunstet ist Anschluss Die POWER BAR darf nur an...

Страница 7: ...Bestandteil unserer Konformit tserkl rung und damit der Betriebszulassung des Ger tes Seriennummern am Ger t und in den original Begleitpapieren insbesondere den Kontroll und Garantiezertifikaten d rf...

Страница 8: ...8...

Страница 9: ...ltage surge protection system which reduces these peaks and thereby helps to avoid potentially terminal damage to the highly sensitive Hi Fi electronics connected to it We are grateful for the faith y...

Страница 10: ...roblem is that the mains supply is usually connected to a wide range of equipment which generates powerful interference such as computers switching units control systems and motors all of which inject...

Страница 11: ...t the indicator LED does not glow If the polarity is set up in this way the marked terminal of each mains supply socket is the phase line and this should be connected to the correspondingly marked ter...

Страница 12: ...Please do not switch it on until it has had plenty of time to warm up to room temperature so that any condensation evaporates completely Connection The device is intended to be connected to a properly...

Страница 13: ...ee certificates must not be removed or modified and must correspond Infringing any of these conditions invalidates conformity and approval and the unit may not be operated within the EC Improper use o...

Страница 14: ...58 cm Basic Version Power Bar 2 3 9 x 16 x 53 cm 6 x 9 x 46 cm Basic Version Kabell nge 2 m Specification Total maximum ratings 230 V Version 230 V 50 60 Hz 16 Aeff any distribution max 3500 W 115 V V...

Страница 15: ...15...

Страница 16: ...elektroakustik GmbH Co KG Herford Deutschland Germany Allemagne...

Отзывы: