background image

Charging the lift unit

RiseAtlas can be used with three different charging systems:

1. Charger station for charging via hand control (Standard version for 50100057)
2. In-rail charging (Accessory for 50100057)
3. End-point charging (Standard version for 50100051, accessory for 50100057)

RiseAtlas is charged with a charger unit that is connected to the charger cables via a DC outlet. The charger should be 
kept in an appropriate location. Note that the charger is a separate unit and can be easily mistaken for another charger. 
Ensure that the correct charger is used, see Technical information. For assembly instructions, see Assembly of charger 
unit.

1) The lift unit is charged via a wall-mounted charger station. Place the hand 
control in the charger station. The charging lamp on the lift unit indicates charging 
for 15 minutes after being activated. Charging continues until the battery is fully 
charged.

2) For in-rail charging, the lift unit is always kept charged, which means that it can 
be left anywhere on the rail and will charge automatically.

3) For end-point charging, the lift unit is placed at the charger station at the end 
of the rail. If the rail system is of the traverse type, the secondary rail is placed at 
the end of the primary rail at which the charger station is located. Check to ensure 
that the battery symbol on the lift unit lights up.

7

M A N U A L

System

RoMedic

TM

Содержание RiseAtlas450M

Страница 1: ...se trolley which readily allows for dismantling of the ceiling lift unit from the rail Visual inspection Inspect lift functions regularly Check to ensure that product is free from damage Before use En...

Страница 2: ...sing the product 13 18 Important information 13 Before use 13 Safe working load 14 Description of functions and symbols 14 Hand control 15 Information panel 16 Preventive service maintenance 16 Emerge...

Страница 3: ...e AB Periodic inspection must be performed at least once a year Use only original spare parts Service and maintenance must be performed according to instructions in the user manual The lift unit must...

Страница 4: ...cm 70 inches above the floor Assembly of charger unit The following is included in the charger station package Holder Charger cup Charger cable EU UK US connectors included fixtures between charger s...

Страница 5: ...H UNLESS OTHERWISE SPECIFIED DIMENSIONS ARE IN MILLIMETERS SURFACE FINISH TOLERANCES LINEAR ANGULAR Q A MFG APPV D CHK D DRAWN 2 Trolley in position for mounting dismounting Trolley quick release Trol...

Страница 6: ...racket into the desired angle Figure 6 III Mount the top bracket and the covers back to their original position CH 90001449 WEIGHT SEE DETAILS SEE DETAILS MATERIAL DATE SIGNATURE NAME DEBUR AND BREAK...

Страница 7: ...r assembly instructions see Assembly of charger unit 1 The lift unit is charged via a wall mounted charger station Place the hand control in the charger station The charging lamp on the lift unit indi...

Страница 8: ...pins that hold the charger plate in place Then the dip switch on the circuit board is set for the desired charging function 2 Check to ensure that the charger plate springs in and out when pressure i...

Страница 9: ...lied to the charger plate see Figure 2 3 Guide the lift unit onto the rail so that the plus on the charging point is on the right side according to Figure 3 4 Mount charger contacts according to Figur...

Страница 10: ...n for 15 min Battery status in rail charging The battery symbol lights green when battery capacity exceeds 50 When the lift unit is activated the battery symbol lights green for 15 minutes If the batt...

Страница 11: ...ey T bracket into the trolley Then rotate the lift unit 90 degrees to lock the QuickTrolleyReleaseBracket into the trolley picture 1 4 below Ensure that the lift unit slides in place and that it can b...

Страница 12: ...on by lifting a person not a user using an approved lifting sling At the same time check both the user manual and electrical emergency lowering function with someone in the lift See section on Emergen...

Страница 13: ...unattended in a lifting situation Warranty does only apply if repairs or alterations are made to the lift by personnel who are authorized RiseAtlas must not come in direct contact with water RiseAtla...

Страница 14: ...accessory Below is a brief description of the functions that are available for caregivers and user Symbols on the product Battery status Emergency stop The lift unit requires service or maintenance Di...

Страница 15: ...done the battery symbol on the lift unit s information display is lit for 2 seconds showing the current battery status If the battery symbol does not light and the lift unit is not activated check tha...

Страница 16: ...heavy Read user manual Often the book symbol will light up at the same time as another symbol lights up indicating that the user should read the user manual before using the lift unit again Night ligh...

Страница 17: ...upplied Allen key in the hole as indicated fig 4 Turn it counter clockwise to lower and clockwise to raise the sling bar Always ensure that emergency lowering is done in an appropriate location NOTE L...

Страница 18: ...l If the lift cannot be run down check to ensure that load is applied to the lift strap that the battery symbol does not indicate low battery charge level that the directional indicators on the button...

Страница 19: ...g bar SlingBarSpreader M side bars can be used as an accessory SlingBarSpreader M open up the lifting sling and provide for a more reclined position SlingBar XS 250 mm article no 70200071 SlingBar S 3...

Страница 20: ...ents containing phenol or chlorine as this could damage the aluminium and the plastic materials If disinfection is needed 70 ethanol 45 isopropanol or similar should be used Storage and transportation...

Страница 21: ...lastic Sound level Unload 55 dB Max load 57 dB Hand control Electronic Emergency lowering Manual and electrical Lifting range 2400 mm 95 inch Lift weight 7 2 kg 15 9 lbs IP class lift unit IP 20 IP cl...

Страница 22: ...nt ABS plastic Sound level Unload 55 dB Max load 57 dB Hand control Electronic Emergency lowering Manual and electrical Lifting range 2400 mm 95 inch Lift weight 7 2 kg 15 9 lbs IP class lift unit IP...

Страница 23: ...30 mm 9 inch Installation height on SlingBar M 337 mm 13 3 inch Article no 50100057 Article no 50100051 1 Outlet for hand control 2 Hand control 3 Lift strap 4 Emergency stop and electrical emergency...

Страница 24: ...Medic offers improvement of both work environment and quality of care and at the same time achieves significant cost savings Always make sure that you have the correct version of the manual The most r...

Отзывы: