background image

 
 

SerialGate User Guide 

 

 

 

 

 

 

 

 

SG-3011DCL/232 related documents 

The following table summarizes documents included in the SG-3011DCL/232 document set. 

 
 
 
 
 
 
 
 
 

If  you  need  brief  information  about  SG-3011DCL/232  please  visit  our  company  website  at 
http://www.solvline.com/. You can view and/or download documents related to SerialGate series 
as well as latest software and firmware updates. Available resources are as follows: 
 

Document 

Description 

SG-3011DCL/232 Spec Sheet 

SG-3011DCL/232 specifications 

SG-3011DCL/232 White Paper 

An easy reading for anyone new to device server. 

Deals with background and technology past, present, 

and future of device servers along with the overview 

of market environment. 

 
All documents are updated promptly, so check for the recent document update. The contents in 
these documents are subject to change without any notice in advance. 
 

 

Document 

Description 

User Guide 

Integration, configuration, and management tasks are 

explained for the administrator 

COM Port Redirector   

User User Manual 

Guide COM Port Redirector by SystemBase 

TestView User Manual 

Description of TestView for testing: 

COM port, TCP, UDP 

Содержание SerialGate SG-3011DCL/232

Страница 1: ...SerialGate SG 3011DCL 232 User Guide Version 1 1 2013 12 23...

Страница 2: ...0 All Initial release Dec 23 2013 1 1 All Revision Copyright 2013 SystemBase Co Ltd All rights reserved Website http www sysbas com Tel 82 2 855 0501 Fax 82 2 855 0580 16F Daerung Post Tower 1 288 Di...

Страница 3: ...6 SG 3011DCL 232 related documents 7 Technical Support 8 2 Getting Started 9 Overview 9 Features 9 Application 11 3 Hardware Content 14 SG 3011DCL 232 exterior 14 SG 3011DCL 232 LED 15 4 Make Connecti...

Страница 4: ...ing 19 Factory Default 24 Reboot 24 6 Application Example 25 Com Port Redirector 25 TCP_Server TCP IP connection from PC to SerialGate 27 TCP_Client TCP IP connection from SerialGate to PC 28 Troubles...

Страница 5: ...Who should read this document This guide is designed for SG 3011DCL 232 users and administrators It is strongly recommended that anyone trying to apply use and maintain SG 3011DCL 232 to read this do...

Страница 6: ...Chapter 4 helps you to connect SerialGate to serial and network environment It ends up with first time boot up and status check Configuration via Web Chapter 5 provides menu by menu guide for setting...

Страница 7: ...3011DCL 232 specifications SG 3011DCL 232 White Paper An easy reading for anyone new to device server Deals with background and technology past present and future of device servers along with the over...

Страница 8: ...technical support team The mail address is tech sysbas com Any kind of inquiries requests and comments are welcome Finally you can call us at the technical support for immediate help Our technical sup...

Страница 9: ...trial metering devices etc SerialGate supports RS 232 serial communication standards under various communication speed meanwhile auto sensing 100baseTX Fast Ethernet and 10baseT Ethernet connection Fe...

Страница 10: ...is as follows Please check all the contents in the box SG 3011DCL 232 1 unit A Class Device This device is registered only for office use and both the seller and the user must be aware of this If not...

Страница 11: ...ous fields Network Serial Communication When the PC and SG 3011DCL 232 are connected to the network and the user gets an access to a device connected to SG 3011DCL 232 from the PC INTERNET LAN LAN PST...

Страница 12: ...tion SG 3011DCL 232 enables a connection not restricted to distance between PC and serial device To enable this feature a user should change its setting to TCP Server TCP Client mode or UDP Server UDP...

Страница 13: ...C Robot arms Human Machine Interface Warehouse rails Medical instruments Inspection equipment controllers Alarming units Home Appliances Electronic Devices Power controller gaming machines Scales Gas...

Страница 14: ...e User Guide 14 3 Hardware Content This chapter provides hardware information of SerialGate including block diagram layout pin specification dimensions and other hardware related issues SG 3011DCL 232...

Страница 15: ...tworking devices such as Ethernet card hub and router SG 3011DCL 232 LED LED Name Status Operation 1 RDY Blink When powered on it will stay on for few seconds and starts to blink when booting is compl...

Страница 16: ...No Signal Description 1 DCD Data Carrier Detection Input 2 RXD Receive Data Input 3 TXD Transmit Data Output 4 DTR Data Terminal Ready Output 5 GND Ground 6 DSR Data Set Ready input 7 RTS Request to...

Страница 17: ...32 that you have If an appropriate power input has been successfully supplied SG 3011DCL 232 will power on and start booting Although there is no LED to check the power status you can check it by LEDs...

Страница 18: ...a fixed IP address SG 3011DCL 232 supports the following options in case that a user does not know IP address Default IP Address 192 168 0 223 The default IP address set for SG 3011DCL 232 is 192 168...

Страница 19: ...e the IP address of the SG 3011PCL A login window shown below will appear The initial ID and password are serialgate and 99999999 without quotes The ID and password can be modified once logged in Netw...

Страница 20: ...erialGate Name the device MAC Address Unique Address Display the MAC Address Connection Type Static Choose whether to leave it as Static IP type or DHCP type IP Address 192 168 0 2 23 Set current IP a...

Страница 21: ...hanging the settings click the Submit button to save and use the Reboot from the menu to restart the device If you exit without saving the modified configuration it will be lost If modified value is n...

Страница 22: ...onnect to the server IP address and the socket number assigned when a certain server waits for connection on the network All data between the socket and the serial port is transferred untouched after...

Страница 23: ...aracter string are to be transmitted from the serial device to a server through SerialGate bypass is set to 0 for the latency time Although it provides immediate sending through SerialGate the server...

Страница 24: ...ered If this button is pressed for longer then 3 second SerialGate will restore factory default settings Pressed for Action Result Less than 3 seconds Press and hold then release after required time p...

Страница 25: ...ser can use serial port connected to SerialGate on the network as if it is a serial port on PC Install COM Port Redirector and set the following steps For installation please refer to Com Port Redirec...

Страница 26: ...SerialGate User Guide 26 In order to correspond to the Redirector setting of PC change the setting in the first serial port of SerialGate as follows...

Страница 27: ...e first port of SerialGate is default 4001 try to connect to IP address and socket number 4001 in Serial Gate when connecting from the PC to the SerialGate As shown below change the Operation Mode to...

Страница 28: ...P IP through the socket program in PC Since it is a connection from SerialGate to a PC change the Operation Mode to TCP_Client and register PC s IP address and socket number to be connected Check the...

Страница 29: ...L 232 are on the same IP segment or can reach each other with a PING command from the host The IP address you assign to SG 3011DCL 232 must be on the same logical network as your host computers e g if...

Страница 30: ...DHCP server and make sure that the server is not set up to load wrong IP addresses into SG 3011DCL 232 Troubleshooting Windows Problems If you are having trouble accessing the connected serial device...

Страница 31: ...t 32 1g Operation Temperature 0 70 Signals RXD TXD RTS CTS DCD DTR DSR RI Humidity Max 90 non condensing LED RDY Green SRL Red Yellow Green RJ 45 Connector LED Speed Green Link Activity Yellow Serial...

Страница 32: ...ort RS232 only SG 1020 Combo RJ 2 x Serial RJ 45 Port RS422 RS485 selectable SG 1020 ALL 2 x Serial DB 9 T B Port RS232 RS422 RS485 selectable SG 1020W ALL 2 x Serial DB 9 T B Port RS232 RS422 RS485 s...

Отзывы: