VR 250 ECH/B 

 

Operation and maintenance instructions 

 
206610 (16-11-2010) 

3

 Systemair 

AB 

   GB 

General 

 

Fig. 1 

 
A) 

Fresh air filter, EU7 

B) 

Rotating heat exchanger 

C) Inlet 

fan 

D) 

Electric re-heater battery, 500 W 

E) 

Extract filter, EU3 

F) Extract 

fan 

G) Control 

equipment 

1) Outdoor 

air 

2) Discharge 

air 

3) 

Supply air to living areas 

4) 

Extract from wet rooms and kitchen 

5) 

Extract from cooker hood (bypass) 

 
VR 250 ECH/B is a complete ventilation unit for supply of filtered and preheated outdoor air to residential 
areas and extract of a corresponding amount of used air from wet rooms and kitchen. The unit is equipped 
with a heat exchanger block to ensure safe and economical ventilation. 
 
VR 250 ECH/B is especially designed for installation in flats and apartments where duct runs, smells and 
pollution from the kitchen extract (cooker hood) often is a great challenge. A damper solution in the  
VR 250 ECH/B makes is possible to connect the unit to cooker hood. The kitchen extract goes directly to 
the extract fan avoiding fumes and pollution to be led into the heat exchanger.  
 
The unit will automatically alternate between winter operation with heat recovery and summer operation 
without heat recovery. 

Содержание VR-250 ECH/B

Страница 1: ...10 02 16 11 2010 VR 250 ECH B Air Handling Unit Operation and maintenance instructions GB GB...

Страница 2: ...operation 5 Manual summer operation 5 Kitchen extraction 6 Maintenance 7 Changing extract inlet filter 7 Changing operation time between filter changes 7 Checking the heat exchanger 8 Checking the fa...

Страница 3: ...ply of filtered and preheated outdoor air to residential areas and extract of a corresponding amount of used air from wet rooms and kitchen The unit is equipped with a heat exchanger block to ensure s...

Страница 4: ...hange Signal heater battery ON Fig 2 The unit is controlled from a separate controller with the following functions Airflow Fan speed Buttons to increase or decrease airflow in 3 steps 4 and 5 fig 2 L...

Страница 5: ...ated but the efficiency will be reduced if the filter is not replaced Operation time 6 9 or 12 months between filter changes can be set on the control panel see installation instructions From factory...

Страница 6: ...cooker is led directly through the extract fan and not through the heat exchanger The capacity of the extract fan is then primarily used for extract from the cooker but a minor airflow is maintained...

Страница 7: ...y Contact your supplier for new filter Operation time between filter changes must be re set after filter change Press button 13 fig 2 for approx 5 seconds Yellow lamp 14 and one of the green lamps 6 7...

Страница 8: ...sary the fans can be pulled out for cleaning with a soft brush Do not use water White spirit can be used to remove obstinate settlements Allow to dry properly before remounting Cleaning extract louver...

Страница 9: ...pulling out the plug for 20 30 seconds 4 Cold supply air a Check set supply air temperature on the control panel b Check if fire thermostat is still alert If necessary reset by pressing the red butto...

Страница 10: ...nintended rotor stop belt breakage defective motor 1 1 Missing zero crossing detector 1 1 Voltage too low 210 V Lamps 6 7 and 8 are flashing in accordance with set inlet air temperatures see Operation...

Страница 11: ...10 02 Systemair AB Industriv gen 3 739 30 Skinnskatteberg Sweden Phone 46 222 440 00 Fax 46 222 440 99 www systemair com 206610 16 11 2010...