End Switches & Electromagnet release
Electrical connection
Terminal switch is used for signaling damper leaf position. As standard
it is connected for signalization of damper leaf closing.
As standard is
delivered type – Schneider Electric: XCKN2118G11.
Technical data
XCKN2118G11
Feeding voltage
AC 240 V, 50/60Hz, 3 A
DC 250 V, 0,1 A
Protection IP
65
Tab. 3 Technical data of terminal switch
Fig. 11 Wiring scheme of terminal switch
XCKN2118G11
Fig. 12 Electromagnet
Connector KSZ 31B
for cable
Ø6 - Ø8
Electromagnet spool EVJ1142
Electromagnet EVJ1142
Fig. 13 Wiring scheme of electromagnet
Electromagnet
Electromagnet is used to release the damper – to close the damper leaf
on the base of electric impulse from the central control unit.
Electromagnet releases the release mechanism, which closes the
damper leaf. As standard is electromagnet EVJ 1142 delivered.
Rated voltage:
230 V/ 50 Hz
24 V/50 Hz
Load factor :
40 %
Rated pull :
10 N
Rated stroke :
max. 10 mm
Degree of protection :
IP55
Version :
push
Mechanical service life: 1 mil. switching
Tab. 4 Technical parameter of electromagnet
Fire damper accessories