6.5

FUEL CHANGE

The gas/nozzle change must be performed by technical qualified personnel in compliance with the
security laws and with this manual.

The constructor disclaims any responsibility in case of damages deriving from wrong transforma-
tion or improper and/or incorrect appliance use.

To replace the gas nozzle, follow the following procedure.
1) Close the gas supply and disconnect the power supply.
2) Unscrew the plug (A) from the ring nozzle holder (C)
3) unscrew the nozzle (B) placed inside the fitting (C)
4) choose the suitable nozzle for the used gas, as indicated in tab. 6.4 at pag. 48
5) Tighten the nozzle into the housing (C)
6) Tighten the plug (A)
7) proceed to start the burner and control efficiency. If there are anomalies, make adjustments following the

procedures outlined in paragraphs 6.3.1 and 6.3.2.

Seal the gas valve regulation body after calibration.

Fig.6.5 Nozzle change

Содержание EOLO BluLine BL 100

Страница 1: ...SUSPENDED WARM AIR HEATERS EOLO BLULINE modulating pre mixed versions AE and AC Rev 04GB1410 GB...

Страница 2: ...3 Loreggia C A P 35010 PADOVA ITALIA Tel 39 049 9355663 r a Fax 39 049 9355699 E mail systema systema it www systema it IMPORTANT Read carefully this manual before starting up the system In order to...

Страница 3: ...series 20 1 8 BURNER EXPLODED VIEW 22 2 ELECTRICAL PLANT 23 2 1 MAIN ELECTRONIC BOARD SCP674V010 GENERAL CHARACTERISTICS 23 2 1 1 OPERATION 23 2 1 2 ALARM OPERATION AND RESET 23 2 1 3 AUXILIARY CONTR...

Страница 4: ...COAXIAL ROOF DISCHARGE TYPE C33 42 5 6 COAXIAL WALL DISCHARGE TYPE C33 42 6 TESTING AND EQUIPMENT START UP 43 6 1 PRELIMINARY OPERATIONS 43 6 2 STARTING AND RUNNING OF THE GENERATORS 43 6 3 SETTINGS 4...

Страница 5: ...standards The manufacturer declines all responsibility in case of damages cau sed by erroneous installation or improper and or incorrect use of the appliance Do not obstruct the mouth of the fan or th...

Страница 6: ...and the exact size according to the gas flow required by the generator that the generator is powered by the type of gas which it is set up for IN CASE OF GAS SMELL Do not operate electrical switches t...

Страница 7: ...ances will be reached higher than 94 ref Hi on the maximum power and higher than 101 ref Hi on the minimum power LOW POLLUTING EMISSIONS The polluting emissions into the atmosphere are minimal particu...

Страница 8: ...0 260 350 560 710 690 1120 1480 AC Total absorbed electrical power W 440 540 580 1120 1140 1160 2260 2580 AE Treated air capacity m3 h 1900 2900 3600 4500 5800 7000 9000 11000 Air throw AE m 9 13 17 1...

Страница 9: ...9 2 5 1 2 1 9 2 5 Part number code 04CEVE0836 04CEVE0809 04CEVE0810 04CEVE0832 04CEVE0834 04CEVE0810 04CEVE0832 04CEVE0834 AC version with standard 6 poles centrifugal fan Data for individual DA MV Fa...

Страница 10: ...ce diagrams AC Fans MV fans referring table 1 4 3 m3 h PA Fan 9 9 1V kW 0 123 P6 1F Flow Characteristics Power Fan 10 10 1V kW 0 373 P6 1F Flow Characteristics Power Fan 10 10 1V kW 0 373 P6 1F Flow C...

Страница 11: ...W m3 h W m3 h PA m3 h PA Fan 12 9 1V kW 0 570 P6 1F Flow Characteristics Power Fan 12 12 1V KW 0 570 P6 1F Flow Characteristics Power Fan 12 12 1V KW 0 570 P6 1F Flow Characteristics Delivery Head Fan...

Страница 12: ...st nr Date 1 2 3 ErP 2015 Air Density 1 20 kg m 3 Installation type B free inlet ducted outlet dB A free field noise measurements at 1 m This test data obtained in a laboratory registered by AMCA for...

Страница 13: ...012 Type Motor Test nr Date 1 2 3 4 ErP 2015 48 1 4 5 b Fans performance curves 10 10 NICOTRA for Eolo 35 and 65 230V 50Hz Air Density 1 20 kg m3 Installation type B free inlet ducted outlet dB A free...

Страница 14: ...0 0 1 0 2 0 3 0 4 0 Current A 250 500 750 1000 1250 Speed rpm 63 63 dB A 63 63 63 64 64 60 60 60 59 60 58 59 57 55 55 55 55 55 54 51 51 51 50 50 50 Electronic speed control RVM 5 three wire connection...

Страница 15: ...V Watt Volt Hz Poles F DD 12 9 14195C S4407 13 05 2013 Type Motor Test nr Date 0 500 1000 Speed rpm 0 00 2 00 4 00 6 00 8 00 Current A 0 50 100 150 200 250 300 350 400 450 500 Static pressure Pa 0 0 0...

Страница 16: ...700 800 Static pressure Pa 0 0 2 0 4 0 6 0 8 0 10 0 Current A 0 500 1000 1500 Speed rpm 65 65 65 65 62 61 61 59 60 57 56 56 50 51 50 Electronic speed control RVM 9 three wire connection 1 230 V 60 Hz...

Страница 17: ...tatic pressure Pa 0 0 2 0 4 0 6 0 8 0 10 0 Current A 0 250 500 750 1000 Speed rpm 66 66 66 dB A 68 69 66 66 66 67 67 64 64 66 63 61 63 61 61 Electronic speed control RVM 9 three wire connection 1 230...

Страница 18: ...750 400 850 780 1285 65 AE 700 290 480 168 290 180 500 900 450 1050 450 885 655 1440 85 AE 700 290 480 168 335 160 500 1000 450 1150 450 885 655 1600 100 AE 700 290 480 168 335 160 500 1150 450 1250 4...

Страница 19: ...290 480 168 290 180 500 900 450 950 950 400 885 655 1440 820 1285 720 85 AC 700 290 480 168 335 160 500 1000 450 1050 1050 400 885 655 1600 820 1285 720 100 AC 700 290 480 168 335 160 500 1150 450 115...

Страница 20: ...1410 SYSTEMA S p A EOLO BLULINE 6 1 6 10 9 13 15 14 2 4 11 5 3 12 8 7 7 6a 7a 6a 7a 7c 7d 7b 1 7 EXPLODED VIEW 1 7 1 Eolo BLULINE AE helicoidal version Fig 1 11 Fig 1 12 1 7 2 Eolo BLULINE AC centrifu...

Страница 21: ...0821 E BL 55 100 AC 94CEVE0823 7b Fans hood E BL 15 25 AC 04CNCO2702 E BL 35 AC 04CNCO2703 E BL 45 AC 04CNCO2700 E BL 55 AC 04CNCO2704 E BL 65 AC 04CNCO2701 E BL 85 AC 04CNCO2705 E BL 100 AC 04CNCO270...

Страница 22: ...Secondary air dial E BL 15 AE AC 94CNOP0022 E BL 25 AE AC 94CNOP0023 E BL 35 AE AC 94CNOP0024 E BL 45 AE AC 94CNOP0025 E BL 55 AE AC 94CNOP0026 E BL 65 AE AC 94CNOP0027 E BL 85 AE AC 94CNOP0028 E BL 1...

Страница 23: ...he maximum 2 Power Boost burner ignition with preset power Y2 and Y1 for the preset time 3 BURNER OPERATION a ON OFF POWER FIX enabled by P 0 By closing TA J9B contact b ON OFF TWO POWERS enabled by P...

Страница 24: ...during the burner ignition in the BOOST period from 0 to 100 50 HH Release firmware ONLY READING Tab 2 1 2 1 3 AUXILIARY CONTROL FAN AUXILIARY CONTROL FOR THE SUMMER VEN TILATION By closing the contac...

Страница 25: ...INDICATIONS SCP674V010 PILOT LIGHT ON Burner on presence of flame PILOT LIGHT ON Temperature excess in the combustion chamber or alarm concerning the pressure switch Burner off till the reset of cont...

Страница 26: ...witch contact normally closed J8C C Pressure switch contact common N O Pressure switch contact normally open SUPPLY OF THE BURNER S FAN blower J8A L N PE Output 230Vac BURNER POWER MODULATION Optional...

Страница 27: ...s LEGEND POWER SUPPLY J1A Interface 230Vac power supply PILOT LIGHTS SIGNALS OF FUNCTIONIG OF FANS OUTPUTS J9A N Neutral output N 230Vac LED_TA Pilot light burner 1 functioning N 230Vac 0 5 A LED_BLK...

Страница 28: ...WORK CONTROL BOARD FOR A SINGLE UNIT 2 5 1 Configuration of the electric board SCP674V010 modulating operation of INET panel LEGEND INET CONNECTIONS all models 1 2 Power supply 230VAC 50 60Hz 3 4 Alar...

Страница 29: ...e zone4 C Common zone4 K4 Key selector zone4 LEGEND INET CONNECTIONS all models 1 2 Power supply 230VAC 50 60Hz 3 4 Alarm relay 3 1 A 230Vac only for preset models C OP External probe only for preset...

Страница 30: ...lded cable for connection of ground control board and the thermal units min imum section 2x0 5 mm2 LEGEND INET CONNECTIONS all model 1 2 Power supply 230VAC 50 60Hz 3 4 Alarm relay 3 1 A 250Vac only f...

Страница 31: ...d the INET control board Using the switch SW2 it is possible to assign an address to each network interface The network control recognize the remote units by the number with which they have been codif...

Страница 32: ...d SCP674V010 JP1 and JP2 CLOSED on A OPEN on B 2 8 CONNECTION DIAGRAM COMBUSTION UNITS AND CE ON OF CONTROL BOARD code 04CEQU1204 Control board with thermostat reset ON OFF switch to control n 01 comb...

Страница 33: ...nd JP2 CLOSED on A OPEN on B 2 9 CONNECTION DIAGRAM COMBUSTION UNITS AND CE ON OFF CONTROL BOARD code 04CEQU1202 and 04CEQU1203 Control board with thermostat reset ON OFF switch to control n 01 combus...

Страница 34: ...r in order to reduce the pressure to the values indicated on tab 6 4 at page 48 Next to the 2nd stage reducer install a manometer scale 060mbar 0 06 bar and regulate the pressure at the values indicat...

Страница 35: ...o cover equally the area to be heated If there were cold air infiltrations from gates windows etc we suggest to install the equipments in a way that the hot air jet is directed towards the cold air so...

Страница 36: ...g s wall using one of the solutions shown on the following figures Fig 4 7 Example of Eolo AE AC wall fixing with brackets B in support A in suspension ATTENTION IN ORDER TO INSTALL A HANGING EOLO PLE...

Страница 37: ...RACKET OPTIONAL It is possible to fix to the wall of the building the generator Eolo BLULINE ONLT THE MODELS 15 25 35 45 55 AE using one of the solutions illustrated in the following figures Fig 4 8 E...

Страница 38: ...intake is from outside and from inside with possibility to regulate the internal external air mixture Pos Description 1 Generator support brackets 2 Centrifugal EOLO generator 3 Air outlet duct 4 Int...

Страница 39: ...and suction type C13 separated The comburent air is taken from the installation room The equipment can be combined with separate ducts for the air intake and the fume are discharged through a wall du...

Страница 40: ...TYPE B23 Pos Description Code Q ty 1 Wall fumes terminals 100 mm with hole cover rosette 04CNTE0445 1 2 Wall air terminals 100 mm with hole cover rosette 04CNTE0446 1 3 Stainless steel joint flexible...

Страница 41: ...Stainless steel joint flexible rigid pipe F 100 mm 00CNGI2542 2 4 Stainless steel flexible air pipe 100 mm 00CNTU0543 ML Pos Description Code Q ty 1 Roof terminals 100mm with Upper border Lead flashin...

Страница 42: ...8 Stainless steel flexible air pipe 100 mm 00CNTU0543 ML Pos Description Code Q ty 1 Coaxial wall terminal 150 mm with hole cover rosette 00CGKI2514 1 2 Upper border 00CNCO2676 1 3 Rigid tube 100 mm L...

Страница 43: ...he gas valve will be commanded in opening 848 Sigma and 822 Nova Mix The gas valve will supply gas at a pressure equal to the depression generated by the fan except for adju stments made to OFFSET and...

Страница 44: ...fan at minimum speed and control the combustion values if necessary readjust OFFSET 4 Control combustion 5 Seal the screws 6 and 9 Pos Descrizione Functioning instructions 1 848 SIGMA valve 2 Electric...

Страница 45: ...lues on combustion at maximum power 8 822 Nova Mix valve Seal the gas valve regulation part after the calibration Fig 6 2 822 Nova Mix valve 1 place the manometer on point 2 of the gas valve to detect...

Страница 46: ...f constructor indication Pos Description 1 Fan 2 Air gas mixer 3 Gas inlet 4 Tightening screw regulator secondary air 5 Primary air inlet 6 Secondary air regulator 7 Secondary air inlet 6 4 ELECTRODES...

Страница 47: ...e follow the following procedure 1 Close the gas supply and disconnect the power supply 2 Unscrew the plug A from the ring nozzle holder C 3 unscrew the nozzle B placed inside the fitting C 4 choose t...

Страница 48: ...5 Consumption at min thermal flow at 15 C and 1013 25 mbar methane G20 m h 1 69 2 33 3 60 4 76 5 82 6 35 8 99 10 58 butane G30 kg h 1 04 1 73 2 68 3 54 4 33 4 72 6 69 7 87 propane G31 kg h 1 30 1 71 2...

Страница 49: ...37 181 127 204 160 161 126 201 126 212 146 Lambda 1 31 1 36 1 27 1 28 1 25 1 29 1 33 1 35 1 3 1 34 1 31 1 34 1 31 1 34 Co2 8 98 8 6 9 33 9 22 9 44 9 16 8 88 8 77 9 1 8 82 8 99 8 88 8 99 8 88 Co ppm 0...

Страница 50: ...iance of the system with local laws and regulations in force failure to comply with the installation instructions set down in the technical notes supplied with the Ap pliance and or the rules of corre...

Страница 51: ...the main switch to 0 and disconnect the appliance from the power supply Close the gas supply valve and disconnect the appliance from the gas mains In the case of change in ownership give all document...

Страница 52: ...To continually improve the products SYSTEMA S p A reserves the right to alter the characteristics with out prior notice...

Отзывы: