SS-300-020 

I56-3536-003R 

 

 

©2010 System Sensor

thRee-yeaR LiMiteD waRRanty

System  Sensor  warrants  its  enclosed  product  to  be  free  from  defects  in  materials  and 
workmanship  under  normal  use  and  service  for  a  period  of  three  years  from  date  of 
manufacture.  System  Sensor  makes  no  other  express  warranty  for  the  enclosed  product. 
No  agent,  representative,  dealer,  or  employee  of  the  Company  has  the  authority  to  in-
crease  or  alter  the  obligations  or  limitations  of  this  Warranty.  The  Company’s  obligation 
of  this  Warranty  shall  be  limited  to  the  replacement  of  any  part  of  the  product  which  is 
found  to  be  defective  in  materials  or  workmanship  under  normal  use  and  service  during 
the three year period commencing with the date of manufacture. After obtaining a Return 
Authorization  number,  send  defective  units  to:  Returns  Department,  RA  #__________, 
Pittway Tecnologica Srl, Via Caboto 19/3, 34147 Trieste, Italy. 

Please  include  a  note  describing  the  malfunction  and  suspected  cause  of  failure.  The 
Company shall not be obligated to replace units which are found to be defective because 
of  damage,  unreasonable  use,  modifications,  or  alterations  occurring  after  the  date  of 
manufacture.  In  no  case  shall  the  Company  be  liable  for  any  consequential  or  incidental 
damages  for  breach  of  this  or  any  other Warranty,  expressed  or  implied  whatsoever,  even 
if  the  loss  or  damage  is  caused  by  the  Company’s  negligence  or  fault.  Some  states  do  not 
allow  the  exclusion  or  limitation  of  incidental  or  consequential  damages,  so  the  above 
limitation  or  exclusion  may  not  apply  to  you.  This  Warranty  gives  you  specific  legal 
rights, and you may also have other rights which vary from state to state.

Please refer to insert for the Limitations of Fire Alarm Systems

Содержание Innovair Flex D2E

Страница 1: ...g in a building s regular fire detection system This device will not operate without electrical power Fire situations may cause an interruption of power The system safeguards should be discussed with your local fire protection specialist This device will not sense smoke unless the ventilation system is operating and the cover is installed For this detector to function properly it MUST be installed...

Страница 2: ...e 2 REMOVE SCREW AND PIVOT DETECTOR AS SHOWN BELOW REPLACE SCREW TO SECURE DETECTOR IN PLACE H0550 00 5 3 Drill the Mounting Holes Remove the paper backing from the mounting template supplied Affix the tem plate to the duct at the desired mounting location Make sure the template lies flat and smooth on the duct 5 3 1 For rectangular side by side mounting configuration Center punch at 4 target cent...

Страница 3: ...two sam pling tubes The differential pressure should measure at least 25 mm of water and no more than 28 2 mm of water Because most commercially available manometers cannot accurately measure very low pressure differentials ap plications with less than 2 54 m sec of duct air speed may require one of the following 1 the use of a current sourcing pressure transmitter per Section 7 2 or 2 the use of ...

Страница 4: ...lor coded to prevent wiring mistakes Improper connections can prevent a system from responding properly in the event of a fire For signal wiring the wiring between interconnected detectors or from detec tors to auxiliary devices it is recommended that single conductor wire be no smaller than 18 gauge The duct smoke detector terminals accommodate wire sizes up to 12gauge Smoke detectors and alarm s...

Страница 5: ...low out the residual aerosol smoke from the chamber and reset the duct smoke detector Use duct tape to seal the aero sol smoke entry hole CAUTION Canned aerosol simulated smoke canned smoke agent formulas will vary by manufacturer Misuse or overuse to these products may have long term adverse effects on the smoke detector Consult the canned smoke agent man ufacturer s published instructions for an...

Страница 6: ...thorization number send defective units to Returns Department RA __________ Pittway Tecnologica Srl Via Caboto 19 3 34147Trieste Italy Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to replace units which are found to be defective because of damage unreasonable use modifications or alterations occurring after the date of manufactu...