System Sensor warrants its enclosed smoke detector base to be free from defects in mate-
rials and workmanship under normal use and service for a period of three years from date 
of manufacture. System Sensor makes no other express warranty for this smoke detector 
base. No agent, representative, dealer, or employee of the Company has the authority to 
increase or alter the obligations or limitations of this Warranty. The Company’s obligation 
of this Warranty shall be limited to the repair or replacement of any part of the smoke 
detector base which is found to be defective in materials or workmanship under normal 
use and service during the three year period commencing with the date of manufacture. 
After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return 
Authorization number, send defective units postage prepaid to: System Sensor, Returns 

Three-Year LimiTed WarranTY

Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a 
note describing the malfunction and suspected cause of failure. The Company shall not 
be obligated to repair or replace units which are found to be defective because of damage, 
unreasonable use, modifications, or alterations occurring after the date of manufacture. 
In no case shall the Company be liable for any consequential or incidental damages for 
breach of this or any other Warranty, expressed or implied whatsoever, even if the loss 
or damage is caused by the Company’s negligence or fault. Some states do not allow the 
exclusion or limitation of incidental or consequential damages, so the above limitation 
or exclusion may not apply to you. This Warranty gives you specific legal rights, and you 
may also have other rights which vary from state to state.

Please refer to insert for the Limitations of Fire Alarm Systems

Содержание B501BHT-2

Страница 1: ...es 15 2 cm Base Height less sensor 2 3 inches 5 9 cm Weight 32 lb 145 gm Operating Temperature Range 32 to 120 F 0 to 49 C Operating Humidity Range 10 to 93 Relative Humidity Electrical Ratings External Supply Voltage 17 to 32 VDC Standby Current 1 0 mA maximum Alarm Current 15 mA maximum Maximum Ripple Voltage 10 of supply voltage Start up Capacitance 200 µF Communication Initiating Loop Supply C...

Страница 2: ... and bases must be tested after installation and as an inte gral part of periodic maintenance Test the B501BHT 2 as follows NOTE Before testing notify the proper authorities that the smoke sensor system is undergoing maintenance and there fore will be temporarily out of service Disable the system un dergoing maintenance to prevent unwanted alarms 1 If configured as in Figure 4 or 5 reverse the pol...

Страница 3: ...for primary alarm signaling C0474 05 UL LISTED COMPATIBLE CONTROL PANEL INTELLIGENT RELAY MODULE FIRST SOUNDER BASE POWER POWER LAST SOUNDER BASE SLC SLC UL LISTED EOL RELAY 24V UL LISTED EOL RESISTOR 47k UL LISTED 24V SUPPLY SLC THIS IS A STANDARD RELAY MODULE CONFIGURED TO REVERSE THE POWER OPTIONAL SOUNDER INTERCONNECT SLC SLC SUP SUP INTELLIGENT MONITOR MODULE SLC NO 1 NO 2 NC 2 COMM 2 COMM 1 ...

Страница 4: ...a Return Authorization number send defective units postage prepaid to System Sensor Returns Three Year Limited Warranty Department RA __________ 3825 Ohio Avenue St Charles IL 60174 Please include a note describing the malfunction and suspected cause of failure The Company shall not be obligated to repair or replace units which are found to be defective because of damage unreasonable use modificat...

Отзывы: