Installation Guidelines

NOTE:

  Refer  to  the  releasing  device  manufacturer’s 

instructions for connection instructions.

Allowable loop resistance is an important specification for 
control  panels  as  well  as  for  smoke  detectors  and  their 
bases.  The  alarm  system  cannot  be  expected  to  operate 
correctly  if  system  components  have  incompatible  allow-
able loop resistances. Therefore, before beginning installa-
tion,  refer  to  the  control  panel  manufacturer’s  loop  resis-
tance specification to ensure that it is listed as compatible 
with  the  System  Sensor  base  and  smoke  detector  being 
installed.

All  wiring  must  be  installed  in  compliance  with  the 
National Electrical Code, all applicable local codes and any 
special  requirements  of  the  authority  having  jurisdiction, 
using the proper wire size. The conductors used to connect 
smoke  detectors  to  control  panels  and  accessory  devices 
should  be  color-coded  to  reduce  the  likelihood  of  wiring 
errors.  Improper  connections  can  prevent  a  system  from 
responding properly in the event of a fire.

Wiring

For  signal  wiring  (the  wiring  between  interconnected 
detectors), it is recommended that the wire be no smaller 
than AWG 18. However, the screws and clamping plate in 
the base can accommodate wire sizes up to AWG 12. The 
use of twisted pair wiring for the power (+ and -) loop is 
recommended to minimize the effects of electrical interfer-
ence.

NOTE: 

 To  ensure  that  electrical  connections  are  super-

vised,  DO  NOT  loop  wires  under  terminals  2,  3, 
and 5 –break the wire at each terminal.

To make electrical connections, strip approximately 3/8” (1 
cm) insulation from the end of each wire. Slide the wires 
under the clamp plate and tighten the terminal screw.

If the base is being installed in a zoned system, check the 
zone wiring before installing the smoke detector head. The 
built-in  shorting  spring  makes  it  convenient  to  do  this. 
After the detector base is wired and attached to the electri-
cal box, position the shorting spring against terminal 3. Use 
the slot in the retaining clip to hold the spring against the 
terminal, as shown in Figure 1. This shorts the negative-in 
and  negative-out  leads  so  that  loop  wiring  can  be  tested 
for continuity.

The  shorting  spring  in  the  base  will  disengage  automati-
cally  when  the  detector  head  is  removed  from  the  base. 
DO NOT remove the shorting spring since it reengages as 
the detector head is turned into the base, completing the 
circuit.

SNAP ON 

DECORATIVE

RING

SCREWS (NOT

SUPPLIED)

DETECTOR

BASE

BOX (NOT

SUPPLIED)

SHORTING

SPRING

C503-00

Figure 1. Mounting base to box:

Tamper-resistance Feature

NOTE:

  DO  NOT  use  the  tamper-resistance  feature  if  the 

System Sensor XR2 Removal Tool will be used to 
remove detectors from the base.

This  detector  base  can  be  made  tamper  resistant  so  the 
detector cannot be removed without the use of a tool. To 
make the base tamper-resistant, break off the smaller tab at 
the scribed line on the tamper-resistance tab, on the detec-
tor mounting bracket (see Figure 3A), before installing the 
detector.

To remove the detector from the base after it has been made 
tamper resistant, remove the decorative ring by rotating it 
in either direction and pulling it away from the base. Then, 
insert  a  small  screwdriver  into  the  notch,  as  indicated  in 
figure 3B, and press the plastic lever toward the mounting 
surface  before  rotating  the  detector  counterclockwise  for 
removal.

D150-03-00 

I56-597-03R

DETECTOR

POWER LOOP

(+)

(–)

ALARM

INITIATION LOOP

FCI

CONTROL PANEL

ALARM RELAY

AUXILIARY CONTACTS

N.O.

12

N.C.

13

C.

14

(2.8 VDC)

(+)     (—)

1        4

ALARM

RELAY

REMOTE

ANNUNCIATOR

OUTPUT

(+IN)   2

3   (+OUT)

SPORTING

SPRING

5    (–IN, –OUT)

(IN)

10

(OUT)

11

ALARM RELAY

8

(IN)

9

(OUT)

FIRST DETECTOR IN LOOP

ALARM RELAY

AUXILIARY CONTACTS

N.O.

12

N.C.

13

C.

14

(2.8 VDC)

(+)     (—)

1        4

ALARM

RELAY

REMOTE

ANNUNCIATOR

OUTPUT

(+IN)   2

3   (+OUT)

SPORTING

SPRING

5    (–IN, –OUT)

(IN)

10

(OUT)

11

ALARM RELAY

8

(IN)

9

(OUT)

FIRST DETECTOR IN LOOP

EOL

RESISTOR

EOL RELAY

(+)

(–)

NOTE:  Schematic

 

Shown for

 

Reference

1

2

3

4

5

8 9

10

11

12

13

14

UL

 LISTED 4-WIRE CONTROL

 P

ANEL

REMOTE

ANNUNCIATOR

RELEASING

DEVICE

(OPTIONAL)

1

2

3

4

5

8 9

10

11

12

13

14

REMOTE

ANNUNCIATOR

POWER LOOP 

+

POWER LOOP –

ALARM CIRCUIT

RELEASING

DEVICE

(OPTIONAL)

EOL RELAY

RESIST

OR

+

+

+

EOL

Figure 2. Typical wiring diagram:

Figure 3A. Activating the tamper-resistance feature:

PLASTIC LEVER

BREAK TAB AT

DOTTED LINE BY

TWISTING TOWARD

CENTER OF BASE.

USE SMALL-BLADED

SCREWDRIVER TO

PUSH PLASTIC LEVER

IN DIRECTION OF

ARROW.

Figure 3B. Removing detector head from base:

C0130-00

C0533-00

C0532-00

Отзывы: