5 - 11
5 Troubleshooting
NA-series Programmable Terminal Hardware User’s Manual (V117)
5-
2 T
rou
blesh
oot
ing
5
5-
2-4 C
auses and C
orr
ection When Y
ou Can
not Go
Online from th
e Sysmac S
tudio
Yes
Yes
No
No
Is the same IP address set for
more than one node (e.g.,
computer or NA Unit) in the
same domain?
Is the Ethernet cable connected to the
Ethernet interface card that is specified to
use for connection in the
Sysmac Studio?
Can the Sysmac Studio go online
with the NA Unit?
A
B
Replace the Ethernet cable
or Ethernet switch.
END
Yes
Yes
No
No
Can the Sysmac Studio go online
with the NA Unit?
Change the Ethernet interface card specification
at the Sysmac Studio or connect the Ethernet
cable to the specified Ethernet interface card.
Refer to the appendices of the
Sysmac Studio
Version 1 Operation Manual
(Cat. No. W504) for the
procedure to specify the Ethernet interface card.
Set the IP address for the personal computer. Use
the default IP address for the NA Unit or connect
the Sysmac Studio to the NA Unit with a USB
cable and set the required IP address.
Содержание OMRON NA Series
Страница 8: ...Sections in this Manual 6 NA series Programmable Terminal Hardware User s Manual V117...
Страница 12: ...CONTENTS 10 NA series Programmable Terminal Hardware User s Manual V117...
Страница 34: ...Revision History 32 NA series Programmable Terminal Hardware User s Manual V117...
Страница 82: ...3 Installation and Wiring 3 22 NA series Programmable Terminal Hardware User s Manual V117...
Страница 164: ...5 Troubleshooting 5 18 NA series Programmable Terminal Hardware User s Manual V117...
Страница 179: ...I 1 I NA series Programmable Terminal Hardware User s Manual V117 Index...
Страница 181: ......