4
Technical Data
4.1
General Electrical Data
Important Note
Do not operate the PROTOUCH-WIDE MONITOR outside of the recommended operating conditions. Otherwise lifetime
and performance will degrade. Operating the board and the display outside of the absolute maximum ratings may
damage the hardware.
Absolute Maximum Ratings
Parameter
Symbol
min
nom
max
Unit
supply voltage
Vdc
10
12/24
36
VDC
storage temperature range
Tst
-20
25
70
°C
operating temperature range
Ta
-20
55
1
°C
operating humidity (not condensing)
Rh
10
90
%
Tab. 9
General Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Symbol
min
nom
max
supply voltage
VDC
12
12/24
24
VDC
operating temperature range
Ta
0
25
40
°C
Tab. 10
General Recommended Operating Conditions
Maximum cable length
Interface
Maximum Length
Comment
Power
2
<3m
CE conformal AC/DC power supply must be used
VGA
<3m
DVI
<3m
Displayport
<3m
<2.7m
USB
<2.7m
Tab. 11
Maximum cable length
1
Depending on installation environment and specific use case; see 4.4
2