IPC/COMPACT4-XS: user documentation
DOC/COMPACT4-XSE; V1.2
© Syslogic Datentechnik AG, CH-5405 Baden-Daettwil, Switzerland, http://www.syslogic.ch
27
/
31
6.2.
EMI / EMC Specification
6.2.1. Relevant Standards
The IPC/COMPACT4 has been designed to comply with the following standards according to
European Union "CE"-requirements:
–
EN 55022
Information technology equipment-
Radio disturbance characteristics-
Limits and methods of measurement
–
EN 55024
Information technology equipment-
Immunity characteristics-
Limits and methods of measurement
–
EN61000-2-2 Generic standard - immunity Standard for industrial
environments.
–
EN61000-2-4 Generic standard - emmission standard for industrial
environments.
–
EN 50121-3-2 Railway applications – Electromagnetic compatibility – Part
3-2: Rolling stock – apparatus
–
EN 55011
Industrial scientific and medical (ISM) radio-frequency
equipment – Electromagnetic disturbance characteristics –
Limits and methods of measurement
6.2.2. Electromagnetic Emission
Test
Limit
Performance
Criteria
Result
Remarks
Stationary interference voltage on the AC
voltage terminals
V-Network 0.15 – 30 MHz
Power supply line
Control and singal lines
EN 55022
Class A
Compliant with
EN 50121-3-2
(referring to
EN 55011)
Radiated E-Field, horizontal and vertical
polarized
E-Field-Anenna 30 – 100 MHz
EUT with all cables
EN 55022
Class A
Compliant with
EN 50121-3-2
(referring to
EN 55011)
Tab. 13 Electromagnetic Emission