IPC/COMPACT4-XS: user documentation
DOC/COMPACT4-XSE; V1.2
© Syslogic Datentechnik AG, CH-5405 Baden-Daettwil, Switzerland, http://www.syslogic.ch
25
/
31
RJ45 to logic
2.5
mm
RJ45 to chassis and PCB boarder
2.0
mm
storage temperature range
Tst
-40
90 °C
Tab. 9 General Absolute Maximum Ratings
Recommended Operating Conditions
Parameter
Symbol
min
nom
max
external power supply
Vext
10
24
30 Vdc
battery backup voltage (Io=100
µ
A)
Vbatt
2.70
3.00
3.60 Vdc
PS/2 connector (P3/P4) power load (+5V)
Ips2
200 MA
operating free-air temperature range
Ta
0
55 °C
Tab. 10 General Recommended Operating Conditions
Electrical Characteristics
(over recommended operating range, unless otherwise noted)
Parameter
Symbol
min
Typ
max
Unit
IPC/COMPACT4-1E(E) specific electrical characteristics
full load power dissipation @ 24Vdc (no external
loads)
Pmax
5.0
6.0
W
IPC/COMPACT4-1F(E) specific electrical characteristics
full load power dissipation @ 24Vdc (no external
loads)
Pmax
6.0
8.0
W
IPC/COMPACT4-1G(E) specific electrical characteristics
full load power dissipation @ 24Vdc (no external
loads)
Pmax
5.5
7.0
W
Non-specific electrical characteristics
Vbatt loading (Vcc=0V, without SocketMemory)
Ibat(off)
2.5
27.5
uA
Vbatt loading (Vcc=5V)
Ibat(on)
1.5
4.0
uA
LOWBAT* trip point
2.35
2.5
2.65
V
VRT trip point (RTC Valid RAM and Time Flag)
1.3
V
Tab. 11 General Electrical Characteristics