1.0
17.09.2010
U. Müller
1.1
10.02.2011
technical data corrected
1.2
26.04.2011
block diagrams corrected, notes added for G
Страница 1: ...n t a t i o n IPC COMPACT4 XS DOC COMPACT4 XSE Revision Date Author Modification 1 0 17 09 2010 U M ller 1 1 10 02 2011 U M ller technical data corrected 1 2 26 04 2011 U M ller block diagrams correct...
Страница 2: ...c Discharge 9 1 7 Life Cycle Information 9 1 7 1 Transportation and Storage 9 1 7 2 Assembly and Installation 9 1 7 3 Operation 9 1 7 4 Maintenance and Repair 9 1 7 5 Warranty 10 1 7 6 RoHS 10 1 7 7 W...
Страница 3: ...c Emission 27 6 2 3 Immunity 28 6 3 Environmental Specification 28 6 4 Mechanical Data 29 7 Hardware 30 7 1 Firmware 30 8 Manufacturer Information 31 8 1 Contact 31 List of Tables Tab 1 Additional Doc...
Страница 4: ...gram 13 Fig 4 IPC COMPACT4 XS 16 Fig 5 Service of battery or Compact Flash card 17 Fig 6 One possible way of mounting the IPC COMPACT4 XS onto the DIN Rail 18 Fig 7 Front view with connector markings...
Страница 5: ...and registered trademarks which are the property of their their respecitve owners IBM PC PC AT PS 2 trademarks of IBM Corporation CompactFlash trademark of SanDisk Corporation PC 104 trademark of PC...
Страница 6: ...t is delivered with power connector but without external power supply and without CompactFlash for OS application storage 1 3 1 IPC COMPACT4 1E E IPC COMPACGP 2ESE IPC NETIPC 4AN E 2 Slot chrome steel...
Страница 7: ...ur distributor 1 4 2 Software The following software products are used together with the COMPACT base board IPC IOCOMSW 1A Sample program code and utilities for x86 based systems 1 4 3 Operating Syste...
Страница 8: ...e support systems patient monitoring systems etc is not allowed The use of the products in potentially explosive atmospheres requires additional external protection circuitry which is not provided wit...
Страница 9: ...static discharge Carefully read the assembly and installation guidelines in this document before unpacking the products Make sure that you have all the necessary items ready including all the small p...
Страница 10: ...utside of the specified recommended operating conditions The warranty also expires if the date code or job number listed on the product is altered or rendered unintelligible The warranty does not incl...
Страница 11: ...controller PC 104 bus 10 30V DC unisolated power supply 2x RS232 interfaces 16550 compatible Fig 1 Functional Block Diagram DRAM Controller DDR2 CompactFlash DIL32 Boot Block Flash Nonvolatile Memory...
Страница 12: ...C unisolated power supply 1x RS232 interfaces 16550 compatible CAN 2 0B Controller SJA1000 isolated interface Fig 2 Functional Block Diagram DRAM Controller DDR2 CompactFlash DIL32 Boot Block Flash No...
Страница 13: ...olated power supply 1x RS232 interfaces 16550 compatible 1x RS422 RS485 half full duplex isolated interface Fig 3 Functional Block Diagram DRAM Controller DDR2 CompactFlash DIL32 Boot Block Flash Nonv...
Страница 14: ...r 1 4 4 3 2 2 CAN Interface Configuration The CAN interface has to be configured according to the customers application Please refer to the IPC COMPAGP 1F documentation 1 chapter 1 4 4 for a detailed...
Страница 15: ...ess 2F8h COM2 Fixed Interrupt 3 COM2 Fixed Duplex half full S301 1 4 Termination 120E 100E none S301 5 6 Pullup down 470E none S301 7 6 Tab 3 Allowable configuration options RS422 485 interface Import...
Страница 16: ...tem with many basic functions The enclosure with its internal electronic system meets EMI RFI electromagnetic standards according to the European CE requirements see paragraph 1 5 Fig 4 IPC COMPACT4 X...
Страница 17: ...parts you must remove the cover by executing steps 1 and 2 of the following instructions Important Notes The battery socket is coded no wrong insertion of the backup battery is possible Handle the fl...
Страница 18: ...the Enclosure There are two possible ways to mount the system onto a DIN Rail DIN Rail clamps can be mounted according to Fig 6 There are two versions of DIN Rails available flat C Rails h 7 5mm and n...
Страница 19: ...I CE cerification correct mounting installation and cabling of the IPC COMPACT4 XS system according to these guidelines is absolutely necessary 5 2 Powering the IPC COMPACT4 XS System The logic voltag...
Страница 20: ...If the input voltage drops below 10V the system doesn t work properly correct operation cannot be guaranteed The best efficiency of the power supply can be achieved if the external input voltage is ar...
Страница 21: ...5 Tab 8 IPC COMPACT4 1G Interfaces 5 4 Grounding In some cases it is recommended to connect the shields of the cables to chassis potential at the entry point into the housing cabinet as shown in Fig 8...
Страница 22: ...ly recommended Fig 9 shows an non isolated system with common chassis ground Some of the communication ports are galvanically isolated ports for more information please refer to the documentation of t...
Страница 23: ...tral Grounding Point I O Communication Link Abschirmung Shield Unisolated Node IPC System Nr 1 IPC System Nr 2 Potential Ausgleichsleitung min 10 mm 2 Kupfer Copper wire for Potential Adjustment min 1...
Страница 24: ...m a s l Ta 25 C 1000 Vrms Isolation CAN to logic AC 60s 500m a s l Ta 25 C 1500 Vrms creepage distance CAN to logic 1 6 mm creepage distance CAN to chassis 2 5 mm IPC COMPACT4 1G E specific ratings is...
Страница 25: ...ating Conditions Electrical Characteristics over recommended operating range unless otherwise noted Parameter Symbol min Typ max Unit IPC COMPACT4 1E E specific electrical characteristics full load po...
Страница 26: ...115 2 kBaud IPC COMPACT4 1G E specific switching characteristcs COM1 baud rate RS232 115 2 kBaud COM2 baud rate RS422 RS485 115 2 kBaud Non specific switching characteristics processor clock standard...
Страница 27: ...ents EN61000 2 4 Generic standard emmission standard for industrial environments EN 50121 3 2 Railway applications Electromagnetic compatibility Part 3 2 Rolling stock apparatus EN 55011 Industrial sc...
Страница 28: ...0 2 7 GHz 80 AM 1kHz EUT with connection cable EN 50121 3 2 10V m 5V m A A Fast transients EFT Common Mode 5 50ns repetion freq 5kHz Controll and signal lines Power supply EN 61000 4 4 2kV 2kV B B Com...
Страница 29: ...netic standards according to the European CE requirements see paragraph 1 5 The figure below shows the IPC COMPCACT4 XS from its three sides Fig 11 Three side view of the IPC COMPACT4 XS enclosure Lab...
Страница 30: ...refore this information may be incompatible with the prototyping board hardware Important Note This document always covers the newest product revision listed in Tab 15 Please contact the manufacturers...
Страница 31: ...heir use If you want to contact the manufacturer directly please send a fax or email message containing a short description of your application and your request to the following address or use one of...