HDMI2.0 KVM Matrix Switcher                       

 

                       

13 

 

 

4.  Serial Port Operation 

4.1. RS232 Control 

Advanced users may need  to  control  the matrix through RS232 serial 
communication. Connect a control PC or control system to the RS232 port of the 
Matrix. API command for RS232 control is available in the separate document 

API Command Set_SCT-MXKVM42-H2U3

”. A  professional RS232 serial 

interface software (e.g. Serial Assist) may be needed as well. 
Before executing the API command through RS232 serial connection, please 
ensure RS232  interface of the device  and the control  PC  are  configured 
correctly. 

Parameters 

Value 

Baud Rate 

115200 bps 

Data Bits 

8 bits 

Parity 

None 

Stop Bits 

1 bit 

Flow Control 

None 

 

4.2. Serial Command Routing 

The  matrix  supports serial command  routing function  to HDBaseT receivers 
from matrix LAN port.     
1.  Users can send commands and receive responses through matrix LAN port 

to HDBT receiver connected 3rd-party devices.   

2.  Each HDBaseT output has a dedicated TCP/IP port on the matrix. 

a)  5001 - serial routing TCP/IP port for HDBaseT output1 
b)  5002 – serial routing TCP/IP port for HDBaseT output2 

3.  API commands are complete transmission,  and not need to add  extra 

terminator. For example, when matrix IP is 192.168.0.100, all data that goes 
to 192.168.0.100  port 5001  will  also output from RS-232 port of matrix 

Содержание SCT-MXKVM42-H2U3

Страница 1: ...SCT MXKVM42 H2U3 HDMI2 0 KVM Matrix Switcher User Manual All Rights Reserved Version SCT MXKVM42 H2U3_2022 V1 0 2...

Страница 2: ......

Страница 3: ...e It may result in electrical shock or burn Using supplies or parts not meeting the products specifications may cause damage deterioration or malfunction Refer all servicing to qualified service perso...

Страница 4: ...tallation and Wiring 9 2 1 Installation 9 2 2 Wiring 10 3 IR Remote Control 12 4 Serial Port Operation 13 4 1 RS232 Control 13 4 2 Serial Command Routing 13 5 Web UI Control 15 5 1 Get Access to the W...

Страница 5: ...tions for easy management 1 2 Features 4x2 KVM matrix switcher with HDMI 2 0 switching and USB 3 0 matrix switching 4x2 2 video matrix supporting 4 HDMI 2 0 inputs and 2 HDBT 3 0 HDMI 2 0 mirror outpu...

Страница 6: ...dded audio from HDBT HDMI OUT 1 2 Multiple control options including front panel buttons IR RS232 and LAN Telnet Web UI 1 3 Package Contents 1 x Matrix 1 x AC Power Cord with EU Pins 2 x Phoenix Male...

Страница 7: ...lly supports audio formats in HDMI 2 0 specification including PCM 2 0 5 1 7 1 Dolby TrueHD Dolby Atmos DTS HD Master Audio and DTS X HDBT Same as HDMI In Out AUDIO OUT Stereo Maximum Pixel Clock 600M...

Страница 8: ...2 2 36bpp Cat 6a U FTP 100m 330ft 1080P 60Hz 4K 30Hz 4K 60Hz Cat 7 100m 330ft 1080P 60Hz 4K 30Hz 4K 60Hz Use Patches Note Patches may be used in the installation and the patches will obviously affect...

Страница 9: ...ent Maximum Distance X Y meter Cable Type Range Supported Video Cat 5e 6 70m 230ft with Patches 1080P 60Hz 4K 30Hz 4K 60Hz 4 2 0 36bpp 30m 100ft with Patches 4K 60Hz 4 4 4 24bpp 4K 60Hz 4 2 2 36bpp Ca...

Страница 10: ...MI HDBT OUT 1 2 is selected for AUDIO OUT Off De embedded audio from HDMI OUT HDMI HDBT 1 2 is not selected for AUDIO OUT 6 AUDIO OUT SELECTOR Press to select one de embedded audio from HDBT HDMI OUT...

Страница 11: ...ts are bound with HDMI IN 1 4 respectively and they also can be set independently through API or Web UI detail information please refer to the separate document API Command Set_SCT MXKVM42 H2U3 or Web...

Страница 12: ...t the cables gently To install the device to a suitable location perform the following 1 Attach the installation bracket to the enclosure using the screws provided The bracket is attached to the enclo...

Страница 13: ...h power USB devices users need to connect a separate power supply to the receiver b By default USB control is in sync mode USB Host 1 4 ports are bound with HDMI IN 1 4 respectively When select one so...

Страница 14: ...ix side RS232 Control Connect to a control PC or control system for RS232 serial control LAN Control Connect LAN port of the matrix to a local network with DHCP server and connect a PC to the same net...

Страница 15: ...l battery inside the remote control of our device is packaged by insulation slice please remove the insulation slice before use 2 Please make sure that the remote is pointed directly at the IR receive...

Страница 16: ...configured correctly Parameters Value Baud Rate 115200 bps Data Bits 8 bits Parity None Stop Bits 1 bit Flow Control None 4 2 Serial Command Routing The matrix supports serial command routing functio...

Страница 17: ...rs can use matrix API to change the serial parameters of 5001 or 5002 port independently according to different connected devices the command is as follows SET UART_CFG prm1 prm2 prm3 prm4 prm5 CR LF...

Страница 18: ...P please ensure the local area network is connected with a DHCP server 2 Get IP address through API commands see the separated document API Command Set_SCT MXKVM42 H2U3 or other tools such as SmartSet...

Страница 19: ...utton in the table to select the input for the output display button turns from white to green once selection is done Video Details Click to enter the following page Port Select one input port to get...

Страница 20: ...upper table For example select HDMI IN 1 as input source for HDMI HDBT OUT1 and select USB host 2 to be connected to USB devices 1 the USB devices 1 will be connected USB host 2 3 Audio Control This...

Страница 21: ...already saved is loaded 5 2 2 General Setting There are three submenus in this page EDID Preset EDID Read HDCP 1 EDID Preset This section allows you to configure EDID settings of each input port Selec...

Страница 22: ...the EDID of the Output port you choose Save As Click to save the read EDID of the output as a bin file to a desired location 3 HDCP This section allows you to enable or disable HDCP capability of eac...

Страница 23: ...ly by the DHCP server connected Static When enabled set up the IP address manually Apply Click to enable the network setting The default setting is DHCP Note When Static is selected please ensure your...

Страница 24: ...Click Browse for the update bin file 2 Click Update to start the Firmware upgrade 3 The matrix will upgrade and reboot automatically when upgrading firmware is completed Please wait for about 30s and...

Страница 25: ...tear Use of supplies or parts not meeting our specifications No certificate or invoice as the proof of warranty The product model showed on the warranty card does not match with the model of the prod...

Страница 26: ......

Страница 27: ......

Страница 28: ...HDMI2 0 KVM Matrix Switcher syscomtec Distribution AG Raiffeisenallee 8 D 82041 Oberhaching bei M nchen Tel 49 89 666 109 330 Email post syscomtec com https www syscomtec com...

Отзывы: