background image

4

5.2 Setting the leakage

 protection

When pressing the   key, the menu for the va-

cation leakage protection appears in the display, 

provided it is activated. 

When  pressing  the    key  again,  the  current 

anti-leakage setting is displayed. 

When  no  key  is  activated  within  30  seconds, 

the display goes back into the locked position. 

5.1 Leakage protection

 

Unlock the keyboard to change values. 

Press  simultaneously  the    and    key  for 

about 3 seconds. The display starts flashing to 

signal that the keyboard is unlocked. 

5. User menu

When  the  device  is  mains-operated,  the 

display always remains active. 

The  leakage  mode  provides  for  a  standard 

supervision of the installation.

The system calculates the volume flown without 

interruption as well as the flow rate.

Should one of the following criteria be exceeded, 

the  device  suspects  a  leakage  problem  and 

closes the main isolating valve.  

•  In  case  the  water  quantity  flown  without 

interruption  exceeds  the  set  limit  for  the 

volume-based leakage (100 - 1500 liters) → 

Message A3 is displayed. 

•  In case the flow rate exceeds 3500l/h for one 

minute → Message A4 is displayed.

•  In  case  of  an  uninterrupted  flow  of  water 

during  2  hours  with  a  setting  of  100  to  400 

liters → Message A9 is displayed.

•  In  case  of  an  uninterrupted  flow  of  water 

during  3  hours  with  a  setting  of  500  to  700 

liters → Message A9 is displayed.

•  In  case  of  an  uninterrupted  flow  of  water 

during 4 hours with a setting of 800 to 1100 

liters → Message A9 is displayed.

•  In  case  of  an  uninterrupted  flow  of  water 

during 5 hours with a setting of 1200 to 1500 

liters → Message A9 is displayed.

Unlock the keyboard, if needed. 

The message „LE“ flashes in the display.

When pressing the   key again, the menu for 

the leakage protection displayed.  

Содержание SYR-Safe-T

Страница 1: ...Instructions of use...

Страница 2: ...ge protection 4 5 3 Deactivating the leak protection 5 5 4 Vacation leakage protection 5 5 5 Setting the vacation leakage protection 6 5 6 Deactivating the vacation leakage protection 6 5 7 Stop valve...

Страница 3: ...into the normal operation mode Make sure that the battery block is correctly po sitioned in the compartment against the internal back wall Close the battery door As an option you can also connect the...

Страница 4: ...of the following criteria be exceeded the device suspects a leakage problem and closes the main isolating valve In case the water quantity flown without interruption exceeds the set limit for the volu...

Страница 5: ...lows for the following settings Press the key to validate and save the changes Press the key to display the current setting Set the desired value by means of the or key Press the key to save the setti...

Страница 6: ...key to save the settings Press the key again to display the current setting of the vacation leakage protection Press the key until the vacation leakage protection is displayed 5 6 Deactivating the vac...

Страница 7: ...play the current sta tus of the leakage protection s stop valve Press the key to display the menu of the lea kage protection s stop valve 5 7 Stop valve In order to change the stop valve s position un...

Страница 8: ...e vacation supervision use the following function When no water is drawn off during 48 hours the main stop valve isolates the system for 3 minutes When the stop valve opens again after 3 minutes the d...

Страница 9: ...ply when the flow rate exceeds 3500 l h Save the change by pressing the key 6 5 Unlocking the device The next step leads to the menu allowing to un lock the device When the SYR Safe T has isolated the...

Страница 10: ...ired status by means of the or key and save the change by pressing the key 6 9 Contact 2 The contact 2 offers many connection possibilities You can connect for instance floor sensors or temperature pr...

Страница 11: ...ise the installation with full Hc or re stricted only floor sensor Hd supervision Save the change by pressing the key Press the or key to define the conditions When selecting the restricted supervisio...

Страница 12: ...e display 8 Emergency unlock function The emergency unlock function is designed to unlock the system manually in case the SYR Safe T isolates the installation and a power fai lure occurs at the same t...

Страница 13: ...s to restart the device 8 1 page 11 Mount the control unit and secure it with the clamp Put the two insulating covers back into place As the position has been changed manually with the emergency unloc...

Страница 14: ...alified installers are authorised to install and service the device Do not clean synthetic parts with solvent based detergents Protect the device and the electronic system against frost When submitted...

Страница 15: ...Type SYR Safe T Leakage protection module Nominal size DN 20 32 Dimensions T 108 mm t 24 mm T1 105 mm t1 76 mm H 307 mm h 174 mm B 120 mm 15 12 Dimensions...

Страница 16: ...has been exceeded Press the key to open the stop valve and eliminate the leakage problem The system has identified a leakage problem at contact IN1 floor sensor Press the key to open the stop valve an...

Отзывы: