![SYR Safe-T Connect Скачать руководство пользователя страница 24](http://html1.mh-extra.com/html/syr/safe-t-connect/safe-t-connect_operating-manual_1421457024.webp)
Technical data
10. Technical data
10.1. Safe-T Connect
Units
Safe-T Connect
Mains adapter voltage
V DC
9
Batteries
4 x AAA
Protection class
IP 21
Max. load on external floating contact
External input IN2
V/mA
not less than 12/20
External output (Out)
V/A
24/2 max.
Max. operating pressure
bar
16
Max. operating temperature
°C
10...30
Working temperature
°C
10...60
Max. required torque
Nm
2
Pressure sensor
bar
0...16
10.2. Flow performance
DN 20
DN 25
DN 32
Δp 0.2 bar
2.0 m³/h
2.3 m³/h
2.5 m³/h
Δp 0.5 bar
3.5 m³/h
3.8 m³/h
4.0 m³/h
Δp 1.0 bar
5.2 m³/h
5.7 m³/h
6.0 m³/h
24