Copyright 2020 by Synthetic Sound Labs LLC - 3650 Digital Sequencer
Page | 10
Purpose
Use this mode to both start and stop the sequencer or start it from a step other than 1 (select your starting step
with the STEP buttons, then send a gate pulse to START IN).
Default
Disabled / Off
Operation
To toggle this mode, press and hold PROG/RESET then RUN (just like for [1X] mode), then hold them for about 1
second. The clock LED will blink twice for enabled and flicker briefly for disabled.
CLOCK OUT (Internal)
Purpose
Send the internal clock out the ACC jack.
Default
Disabled / Off
Operation
Press and hold PROG/RESET, then ACC and hold for 1 second. The ACC LED will BLINK twice to let you know that
CLOCK OUT is enabled and will FLICKER when it has been disabled.
Important Notes:
ACC will no longer be sent out this jack, but it can still be programmed into sequences. The ACC jack will still
operate normally when using an external clock.
CHANGE ON CLOCK MODE
Purpose
Normally if the 3650 is running and you select a new song or sequence to play, it waits until the current one has
completed before switching to the new one. You can change this so that the song or sequence is switched on
the next clock by enabling CHANGE ON CLOCK mode.
Default
Disabled / Off
Operation
To enable this mode, press and hold PROG/RESET, then STEP UP, then hold both buttons for 1 second. STEP #15
LED will blink twice for enabled and flicker for disabled.