12.10.1 Installation
A KTY84 temperature sensor installed on a drive has two signal lines; refer to the
【
Wiring and Signals
】
section for
wiring diagrams.
12.10.2 Drive Parameters Setting
Parameter
Parameter Name
Range
Default
Pn-740
Enable KTY84 Thermal Protection
0~1
1
Pn-741
Motor KTY84 Thermal Protection Level
80~150 (
℃
)
120
Pn-742
Encoder Int. KTY84 Protection Lv.
0~145 (
℃
)
0
Pn-743
Encoder Ext.(1) KTY84 Protection Lv.
0~145 (
℃
)
0
Pn-744
Encoder Ext.(2) KTY84 Protection Lv.
0~145 (
℃
)
0
Pn-746
2nd Encoder Int. KTY84 Protection Lv.
0~145 (
℃
)
0
Pn-747
2nd Encoder Ext.(1) KTY84 Protection
Lv.
0~145 (
℃
)
0
Pn-748
2nd Encoder Ext.(2) KTY84 Protection
Lv.
0~145 (
℃
)
0
Pn-74A
Disable Encoder Int. Thermal
Protection
0~1
0
Pn-74B
Disable Encoder Ext.(1) Thermal
Protection
0~1
0
Pn-74C
Disable Encoder Ext.(2) Thermal
Protection
0~1
0
Pn-74E
Disable 2nd Int. Thermal Protection
0~1
0
Pn-74F
Disable 2nd Ext.(1) Thermal Protection
0~1
0
Pn-750
Disable 2nd Ext.(2) Thermal Protection
0~1
0