![Synrad Novanta OEM ti Series Скачать руководство пользователя страница 20](http://html1.mh-extra.com/html/synrad/novanta-oem-ti-series/novanta-oem-ti-series_user-manual_1421187020.webp)
TI-SERIES SIDE PANEL (SA AIR-COOLED MODELS ONLY)
PAGE
|
20
Keyswitch (Keyswitch models only) – Enables/disables operation of the laser. Laser is enabled when
the Keyswitch is turned to the ON position. Turn the Keyswitch OFF to disable lasing.
USER I/O Connector – Provides a connection point for auxiliary output power as well as input and
output signals. Refer to User I/O connections in the Technical Reference chapter for pinouts and signal
descriptions.
WATER IN Port (water-cooled models only) – Labeled IN, this connection provides the cooling water
inlet to Laser’s water-cooling system.
WATER OUT Port (water-cooled models only) – Labeled OUT, this connection provides the cooling
water outlet to Laser’s water-cooling system.
Figure 2-3 OEM ti-Series side panel controls and indicators. (Air-cooled ti60 OEM shown).
ti-Series side panel (SA air-cooled Models Only)
DB-9 connector – provides an aux5 V power source as well as +48 VDC for powering 48 V cooling
fans. The +5 VDC output is protected by a 0.5 A self-resetting fuse while both +48 VDC outputs are
sourced directly from the user’s 48 V DC power supply and protected by internal 1.1 A self-resetting
fuses. Refer to DB-9 connections in the Technical Reference chapter for pinouts and signal descriptions.
Important Note: The pinout and functionality of the side-mounted DB-9 connector on the ti-
Series SA model lasers is not the same as the DB-9 connector on t-Series (t70i SA model) lasers.
See the Technical Reference Chapter in this Manual for details.
Содержание Novanta OEM ti Series
Страница 1: ...ENGINEERED BY SYNRAD OEM ti Series User Manual...
Страница 26: ...TI60 LABEL LOCATIONS PAGE 26 Ti60 label locations Figure 3 1 Ti60 hazard label locations...
Страница 27: ...TI80 LABEL LOCATIONS PAGE 27 Ti80 label locations Figure 3 2 Ti80 hazard label locations...
Страница 28: ...TI100 LABEL LOCATIONS PAGE 28 Ti100 label locations Figure 3 3 Ti100 hazard label locations...
Страница 32: ...EUROPEAN UNION EU REQUIREMENTS PAGE 32 Table 3 1 Class 4 safety features...
Страница 34: ...EUROPEAN UNION EU REQUIREMENTS PAGE 34 Figure 3 4 ti60 Declaration Document...
Страница 35: ...EUROPEAN UNION EU REQUIREMENTS PAGE 35 Figure 3 5 ti80 Declaration document...
Страница 36: ...EUROPEAN UNION EU REQUIREMENTS PAGE 36 Figure 3 6 ti00 Declaration document...
Страница 52: ...USER I O CONNECTION SUMMARY PAGE 52 Figure 4 5 User I O pinouts Table 4 3 User I O pin descriptions continued...
Страница 55: ...INPUT SIGNALS PAGE 55 Table 4 5 Input signal table continued...
Страница 65: ...DB 9 PIN DESCRIPTIONS PAGE 65 Table 4 9 Side mounted DB 9 pin descriptions continued...
Страница 73: ...REMOTE INTERLOCK FUNCTIONS PAGE 73 Table 4 10 Ti60 general specifications continued...
Страница 74: ...REMOTE INTERLOCK FUNCTIONS PAGE 74 Table 4 11 Ti80 general specifications...
Страница 75: ...REMOTE INTERLOCK FUNCTIONS PAGE 75 Table 4 11 Ti80 general specifications continued...
Страница 76: ...REMOTE INTERLOCK FUNCTIONS PAGE 76 Table 4 12 Ti100 general specifications...
Страница 77: ...REMOTE INTERLOCK FUNCTIONS PAGE 77 Table 4 12 Ti100 general specifications continued...
Страница 79: ...TECHNICAL DRAWINGS PAGE 79 Figure 4 26 Fan cooled ti60 ti80 package outline and mounting dimensions...
Страница 82: ...TECHNICAL DRAWINGS PAGE 82 Figure 4 29 Ti Series HS Outline and Mounting...
Страница 83: ...TECHNICAL DRAWINGS PAGE 83 Figure 4 28 Ti 100p Outline and Mounting...
Страница 84: ...TECHNICAL DRAWINGS PAGE 84 Figure 4 29 Ti 100 Fan Outline and Mounting...
Страница 85: ...TECHNICAL DRAWINGS PAGE 85 Figure 4 30 ti Series packaging instructions...
Страница 93: ...MAINTENANCE TROUBLESHOOTING PAGE 93 Table 4 14 Status Signals...
Страница 99: ...MAINTENANCE TROUBLESHOOTING PAGE 99...
Страница 105: ...APPENDIX PAGE 3 This page is intentionally left blank...