If after clicking ‘Install’ within the Syngene dialogue box you are presented with an error message: 

‘Unable to run installation program. CD may be corrupted’, then click ‘OK’. Browse for the install.bat file 

on the CD and right click on it and select ‘Run as administrator’. Within the resulting User Account 

Control dialogue box click ‘Continue’ and now GeneTools will install (continue from “Follow the 

instructions….”).

NB

GeneTools needs to be installed  and licensed to activate both the Effective Pixels and Focus 

Indicator features in GeneSnap, the acquisition software.

NB2

Within GeneSnap, images can be automatically transferred to GeneTools using the Send to 

GeneTools icon. For Windows VISTA in order for this link to operate you need to perform a mouse right 

click on the GeneTools desktop icon and select Run as administrator. This only needs to be performed 

once and now all users can use this function.

Start the GeneSnap program by double clicking the icon on the Windows desktop.

Place the UV/EtBr filter with the thread pointing upwards in the filter drawer (found below the 

camera on the top of the InGenius LHR unit). This filter can be interchanged with other filters for 

different dyes.

Using GeneSnap

Image capture and enhancement is carried out within

GeneSnap 

(if the program does not open 

automatically simply double-click on the GeneSnap desktop icon).

You will now see the GeneSnap User box.

Type into the space your name and click the OK button. This is now your configuration and any 

changes you make to the way you use or set-up the program will be stored as defaults under your 

name. Each user can enter a name or title for their own individual user preferences so that whenever 

you start InGenius LHR and enter a particular name at the log-in stage the system adapts for that 

user’s preferred settings. In future you only need select your name from the drop down list.

GeneSnap will now fully open and you will see an image capture window appear. If the capture window 

is not visible at any time, click on the camera icon at the top of the screen

To obtain a live image, click the green live button within the image capture window.

The image capture window will now show the current camera view.

Open the cabinet and place the sample on the UV transilluminator or visible light converter. The 

converter is placed on the transilluminator.

Place the sample on the UV transilluminator or 

visible light converter and close the door until 

the interlock clicks.
Select the appropriate light source -
Trans UV or overhead white
Epi UV (long or short) or Epi White if options 

purchased

PowerOn/off

Adjust Aperture, Zoom and Focus 

settings manually until a suitable image 

is displayed. 

Aperture

Zoom

Focus

Содержание InGenius LHR

Страница 1: ...port on the PC until the GeneSnap Camera drivers have been installed Connect electrical power leads to each component but DO NOT SWITCH ON AT THIS TIME Switching on with the Syngene supplied PC Attach the free end of the camera USB cable to a USB 2 port on the PC Ensure it does not share a paired port with a slower device for instance a mouse otherwise this will compromise the response time of the...

Страница 2: ...Image capture and enhancement is carried out within GeneSnap if the program does not open automatically simply double click on the GeneSnap desktop icon You will now see the GeneSnap User box Type into the space your name and click the OK button This is now your configuration and any changes you make to the way you use or set up the program will be stored as defaults under your name Each user can ...

Страница 3: ...ab the image The camera icon will turn GREEN To return to a live image simply click the GREEN camera icon and it will return to RED and the camera is again showing the current sample Further controls Exposure time Above we grabbed an image in real time using the standard exposure setting of the camera However in some instances you may wish to extend the exposure time to resolve fainter bands In th...

Страница 4: ...abbed image is displayed in the image window and the lighting is automatically switched off Printing When an image is grabbed the PRINT icon is available Click this to send a copy of the image to the thermal printer for a hard copy output Saving the image You have the choice of either selecting FILE SAVE AS or FILE EXPORT In the first case the image can be saved in the Syngene secure SGD format fo...

Отзывы: