40
PROGRAMMING
Line 1 of the first brew group control screen indicates the current temperature of the brew tank as measured
by its probe. Once this temperature reaches the set point, it will continuously cycle up and down by small
increments as the electronics balance the temperature. This line also indicates the active program (PRG1 in
this case). Changing the active program will update the settings on the lines below.
Line 2 is indicating the set point of 202.0°F (94.4°C).
Line 3 indicates the length of time preinfusion is set for in the current program. When starting a shot in MP or
VP mode, preinfusion will allow line pressure water to soak the puck for as long as indicated before moving
on to the next brew phase. Setting the preinfusion time down to 0.0 seconds will skip the preinfusion phase
in MP and VP modes. One step lower than 0.0 is the
“
MAN
”
setting, which will require the operator to exit
the preinfusion phase manually in MP mode, and will skip preinfusion in VP mode.
Line 4 indicates the length time set for the ramp
-
up phase in the current program. This option will ONLY be
visible on MVP Hydra models. Ramp
-
up time begins once the preinfusion stage has finished.
To cycle to the next display screen, press the down button.
Menu Level 1: Group 1, Program 1
Factory Settings:
The factory settings for MVP Series machines are as follows:
Brew Group Temperature
203°F
Steam Tank Temperature
250°F
Brew Mode
M (Manual)
Right
-
Hold Save Lockout
Locked (To Unlock refer to page 51)
Enabled Programs
1 & 2 Enabled (3
-
6 Disabled)
Temperature Units
Fahrenheit
Program 1:
Program 2:
Preinfusion
4 seconds
Preinfusion
4 seconds
Ramp Up
2 seconds
Ramp Up
2 seconds
Ramp Down
92%
Ramp Down
92%
Total Water Count
280
Total Water Count
380
Содержание MVP
Страница 12: ...12 INSTALLATION DIMENSIONS ...
Страница 26: ...26 HYDRAULIC SCHEMATIC MVP ...
Страница 27: ...27 HYDRAULIC SCHEMATIC MVP HYDRA ...
Страница 34: ...34 ELECTRICAL SYSTEM Main Electronics Board MVP MVP Hydra ...
Страница 38: ...38 ELECTRICAL SYSTEM Electrical Schematic ...
Страница 44: ...44 PROGRAMMING Brew System Error Codes ...
Страница 45: ...45 PROGRAMMING Brew System Error Codes ...
Страница 46: ...46 PROGRAMMING Brew System Error Codes ...
Страница 48: ...48 PROGRAMMING Steam System Error Codes ...
Страница 49: ...49 PROGRAMMING Steam System Error Codes ...
Страница 50: ...50 PROGRAMMING Steam System Error Codes ...
Страница 71: ...71 TEMPERATURE OFFSETS ...