background image

Synergy Safety Isolation Switch for underwater cutting / welding

IMCA D037
IMCA D023 
IMCA D018

DESIGN for Surface Oriented (Mix Gas) Diving Systems
Design for surface oriented (air) diving systems
Code of practice for the initial and periodic examination, testing 
and certification of diving plant and equipment

Operating Instructions

Description

Ensure the unit is situated in a location so the supervisor or welding co-ordinator can operate 
the switch easily.
It is important that the welding cables coming from the welding power source are connected 
to the Isolation Switch so that the '+' and '-' terminals match.
If you are using a power source fitted with a polarity switch, still make sure the welding cables 
match like-for-like and set the switch on the power-source to negative (-Ve).

NOTE 1:

The panel, (top left side) indicates by use of the symbols 'A' and 'B' which polarity may be selected.
The desired polarity will depend  on whether the welding stinger cable or the return (earth) 
cable is connected to either 'A' or 'B' terminals.
The terminal connections fitted to each Firefly unit are standard DIN (35-50mm2) plugs/socket 
(see duty cycle table for ratings).
Ensure you only use approved standard DIN cable connections.
Ensure you connect cables from the welding power-source to the correct side on the Firefly unit.
These should be connected to the panel plug side, as marked on the panel – TO WELDING PLANT.
Ensure you connect like-for-like, matching the polarity symbols to the welding power-source.
Once the cables from the welding power-source are connected, turn on the machine and check to 
see that the volt meter registers (no need to connect the welding cables to the diver yet).
The volt meter is a zero centred meter and so the needle should rise in an upwards direction.
If the meter falls (drops) in a downward direction, then the cables are not matched like-for-like! 
(Check connections and/or polarity switch and re-test).

NOTE 2:

When using the on/off knob, do not use excessive force, particularly when making COLD, as the 
switch will operate with the minimum of resistance.

Connect the cables to the power-source and ensure the machine is 'on'. 
Test whether the indicator light operates correctly, pull the red on/off knob to make a live (HOT) 
connection; the indicator lamp will now illuminate.
By pushing the red on/off knob down (making is COLD) the indicator light will extinguish.
This procedure now ensures the correct set-up and you are ready to connect the welding cables 
to the diver.
Should the lamp fail to illuminate, then the bulb may have blown. (Please return your unit for inspection).

Sr.

1

2

3

Polarity changes may then be set on the Isolation switch as set out below.
4
5
6

7

8
9
10
11
12

13
14

15

All Isolation switch units are also fitted with an indicator lamp.
16
17

18
19

20

SYNERGY UW CUTTING /WELDING SAFETY ISOLATION SWITCH # SY-BRUW-CWS

Содержание SY-BRUW-CWS

Страница 1: ...AFETY ISOLATION SWITCH SY BRUW CWS PRODUCT CERTIFICATE EC Attestation of Conformity In Compliance with following Directives Machinery Directive 2006 42 EC Low Voltage Directive 2014 35 EU Pressure Equ...

Страница 2: ...e connected to the panel plug side as marked on the panel TO WELDING PLANT Ensure you connect like for like matching the polarity symbols to the welding power source Once the cables from the welding p...

Страница 3: ...vertical direction to make it HOT and push down to make it COLD NOTE 2 When using the on off knob do not use excessive force particularly when making COLD as the switch will operate with the minimum o...

Страница 4: ...of which is as shown on the data label affixed to the panel see copy below As the switch is fitted in an enclosed space the duty cycles are adhered too otherwise serious overheating may occur If you n...

Страница 5: ...e The links to the following file numbers NRNT2 E181430 and NRNT8 E181430 NOTE Access to the UL site has changed you will now have to register to utilize this website although this can be done free of...

Страница 6: ...degrees C The voltage drop across the unit was 397mV and the switch performed satisfactorily during the test Enclosure are available in three models large and small steel and a utility case Material...

Страница 7: ...SYNERGY INFRASTRUCTURE...

Страница 8: ...4 00971505648178 00447951966260 www synergyequipment com ram synergyequipment com info synergyequipment com SYNERGY UW CUTTING WELDING SAFETY ISOLATION SWITCH SY BRUW CWS PRODUCT CERTIFICATE EC Attest...

Отзывы: