SYNERGY UW CUTTING /WELDING SAFETY ISOLATION SWITCH # SY-BRUW-CWS
Once the cables from the welding power-source are
connected, turn on the machine and check to see
that the volt meter registers (no need to connect the
welding cables to the diver yet). The volt meter is a
zero centred meter and so the needle should rise in
an upwards direction. If the meter falls (drops) in a
downward direction, then the cables are not
matched like-for-like! (Check connections and/or
polarity switch and re-test).
All Isolation switch units are fitted with a large,
red bulbous on/off knob. To operate, ,simply
pull in a vertical direction to make it HOT and
push down to make it COLD.
NOTE 2: When using the on/off knob, do not use
excessive force, particularly when making COLD,
as the switch will operate with the minimum of
resistance.
All Isolation switch units are also fitted with an indicator lamp.
Connect the cables to the power-source and
ensure the machine is 'on'. Test whether the
indicator light operates correctly, pull the red
on/off knob to make a live (HOT) connection; the
indicator lamp will now illuminate. By pushing the
red on/off knob down (making is COLD) the
indicator light will extinguish. This procedure now
ensures the correct set-up and you are ready to
connect the welding cables to the diver. Should
the lamp fail to illuminate, then the bulb may have
blown. (Please return your unit for inspection).