Parallel Fixing
Installation and Maintenance Instructions:
Using the templates provided, mark and drill pilot
holes into the door and frame.
Using the templates provided, fix the mechanism
to the door as well as the armset and the parallel
arm bracket.
Ref 90°
1
2
3
Rotate the bottom pinion at approximately 90°
with a wrench as illustrated and then assemble
the main arm.
Closer Adjustments
1
0°
160°
4
Make sure the main arm is parallel to the door. Then
attach the connecting arm.
www.synergyhardware.co.uk
Maintenance
1.Once the unit has been correctly
fitted it is recommended that
periodic checks (every six
months) are carried out to ensure
all fixings are tight and the door
closes freely and positively into
the frame, without slamming.
2.A light oil lubricant (non-graphite)
should be applied to the moving
joints and exposed pivot points.
After Installation
1.When the closer operates to close
the door from its maximum opening
position, it should ensure the lock
latchbolt and any seals are overcome
and the leaf returned into its frame.
2.When the door is slightly open and
the latch bolt resting against the
strike, release the door to ensure the
leaf fully closes into its frame.
Warning
1.Please note the minimum power size requirement for fire / smoke
door assemblies is 3 as required by Approved Document B.
2.Do not install mechanical hold open devices on fire / smoke door
assemblies.
3.Take care not to exceed the maximum opening angle as detailed
above.
4.Care and attention must be taken when adjusting any of the units
control valves to avoid damage through over adjustment.
5.All Synergy Door Closer units are sealed for life and the internal
components assembled under high load, therefore, tampering
with the mechanism is to be strictly avoided.
Fixing Instructions for :
S150 Series
Door Closer
Power Selectable EN 2-4
APPROVED
PRODUCT
CF5294
CPR
AD5191
2812
14
EN1154:1997+ A1:2002
3 8 42 1 1 3
After ensuring all fixings are tightened, operate the door closer to check its performance, making
adjustments as necessary.
Fast
Slow
No.2 Latching
No.1 Closing
Fixing in Fig.66
Max.
Door width
Max.
Door weight
Power
size
Door opening
Max.
3
950mm
60Kg
160°
www.synergyhardware.co.uk