Currently, the system only support and communicate with smart-UPS function of
APC (American Power Conversion Corp.) For UPS, Please take reference from
http://www.apc.com/
.
First, interconnect via RS-232 cable between the system and UPS in order that
the system can communicate with APC UPS. Then set up the shutdown values
when the power is broken. UPS of other vendors can work fine, but they have no
such function.
UPS Type
Select UPS Type. Choose Smart-UPS for APC, None
for other vendors or no UPS.
Shutdown
Battery Level
(%)
When below the setting level, the system will issue
shutdown. Setting level to
“0”
will be disabled.
Shutdown
Delay (s)
If power failure occurred, and not return back in the
setting value period, the system will issue shutdown.
Setting delay to
“0”
will be disabled.
Shutdown
UPS
Select ON, when power is broken, UPS will shutdown
by itself after the system shutdown successfully. After
power comes back, UPS will start working and notify
system to boot up. OFF will not.
Status
The status of UPS.
“Detecting…”
“Running”
“Unable to detect UPS”
“Communication lost”
“UPS reboot in progress”
“UPS shutdown in progress”