Interfacing the host is performed via the Master unit. Communication 
between the Master unit and the terminals is performed at 19200 bps.

Downloading card numbers from Master to terminals

As of Master version 3.20 there is an additional option “Send offline list to 
Access units”. All card numbers that are marked as (see Falcon | Personnel | 
Card Type | Active - Allowed offline)

 Active - Allowed offline

 will be sent 

from the Master to the terminals. When communication is stopped the Termi-
nal will enable access for the cards as mentioned above.

PRX-40/A supports this option as of version 2.04.

SY-11 supports this option as of version 1.07.

4.1

Communication cables characteristics

Follow the listed guidelines when installing the communications cables:

The cable should not be installed near EMI factors, such as:

Motors, generators, alternators, and transformers

Air conditioners, elevators

Radio/television transmitters, signal generators and internal communica-
tion networks

Cables: within 30 cm. (1 foot) of power lines of less than 5 KVA.

Cables should not be within 60 cm. (2 feet) of power lines in the 5-10 
KVA range.

Cables should not be within 1.5 meters (5 feet) of power lines of more than 10 
KVA. The cables should not run parallel to power lines for more than 15 
meters (49 feet). 

It is best to use a single cable for the communication line. If it is not possible 
to use a continues cable only one indoors connection is allowed, constructed 
in one of these options:

1.

Using two connectors with appropriate shielding and cover.

2.

Using a connection box.

For aerial installation, use N.Y.Y. shielded cables.

Содержание PRX-40/A Proximity SY-11

Страница 1: ...Stand Alone Terminals PRX 40 A Proximity SY 11 Magnetic Barcode Product Manual...

Страница 2: ...l content in any manner is prohibited No patent liability is assumed with respect to the use of the information contained herein While every precaution has been taken in the preparation of this manual...

Страница 3: ...rs is simple while maximum security is enabled by using the set up 8 digit code the default number is 12345678 maximizing security In stand alone mode these units grant secure access for approximately...

Страница 4: ...hus the badge will receive maximal energy PRX 40 A If you are installing more than one Synel reader make sure the readers are installed at a distance of at least 50 cm from one another a distance long...

Страница 5: ...back panel and use it to mark the position of the cable hole center of panel Drill the cable hole in the wall 4 Drill the two fastening holes in the wall 5 Connect the cable wires via middle hole or...

Страница 6: ...or Code 1 Vin Power Power Input Red 2 Gnd Black 3 TxRx RS 485 Grey 4 TxRx RS 485 Purple 5 TxD RS 232 White 6 RxD RS 232 Dark Green 7 Alarm Brown 8 Relay common C Blue 9 Normally Closed N C Yellow F ro...

Страница 7: ...tion Present Color Code 10 Normally Open N O Orange 11 Bell 1 Pink 12 Bell 2 Light green 13 Sensor input Dry contact or AC DC Sensing regard jumper JP23 settings Light Blue 14 Brown White Connector De...

Страница 8: ...When JP9 is 2 3 ON SEN 1 2 SEN 1 1 Sensor AC Terminal Block P3 Pin Signal Description P2 1 Common Relay P2 2 SEN1 1 2 Sensor input AC DC dry con tact P2 3 N C Relay Normally closed P2 4 SEN1 2 P2 5 N...

Страница 9: ...n JP12 SMD Tamper switch enabled 1 2 closed Tamper switch disabled 2 3 closed 2 3 closed JP20 T H Closed Stand alone Open Online with Master Closed JP21 T H Contacts switching protection in DC closed...

Страница 10: ...Value Function Defaults Default JP5 ON OFF Work Description ON Burn Position JP6 ON OFF Stand alone ON Online JP7 Connect Disconnect Termination resistor Disconnect JP8 ON OFF Spike overvoltage prote...

Страница 11: ...e below can be used only after completing set up mode as follows Step 1 Press 3 times simultaneously on keys 1 2 each time will be fol lowed by a short beep and an orange led will be lit Step 2 Enter...

Страница 12: ...st Group or list Group Parameters 54 1 click 2 clicks 2 clicks 1 16 clicks Group number 01 03 Start position 01 22 Length 01 16 Group data depends on length Sensor mode 30 0 1 Door open request Door S...

Страница 13: ...A only There is a different code for each employee Duress code enable disable 50 0 1 Disable Enable Activating alarm and relay output Card list type 35 1 Black list Rejected 0 White list Accepted 0 Fi...

Страница 14: ...s 7 8 simultaneously in order to revert to nor mal mode press Enter in terminals that consist of such a key Mode 6 only with PRintX Delete card using keyboard 23 Card number Insert card by Index 24 1...

Страница 15: ...r each keyed in card number 2 short beeps will indicate that the number was registered successfully After keying in all card numbers press 7 8 simultaneously mandatory press Enter in terminals that co...

Страница 16: ...nly and the device is currently in mode 5 or 6 these cards will now be allowed access without fin gerprint verification Note Whenever a task is completed successfully a LED flashes and the buzzer beep...

Страница 17: ...You can change a Global Code by way of Instruction Code 15 After entering Programming Mode enter 15 and afterward a four digit number that will be the new Global Code Set New Master Code The Master Co...

Страница 18: ...Normally Open 1 The sensor will function as Normally Closed Fingerprint operation mode Code 36 0 No auto identification 1 Auto identification mode Alarm mode Code 51 0 Latch The alarm does not go off...

Страница 19: ...meters Refer to how the proximity track will be read Reset alarm In set up mode after keying in code 51 key in 4 to shut off the alarm 2 digits Start position 01 37 Card number offset 2 digits Length...

Страница 20: ...s characteristics Follow the listed guidelines when installing the communications cables The cable should not be installed near EMI factors such as Motors generators alternators and transformers Air c...

Страница 21: ...ectrical characteristics Output relay rating 24Vdc 2 A Alarm sensor output TTL level mx 16 mA Alarm set at High Sensor Input 9 18V 10mA in Non dry contact mode Power supply 9 to 15 Vdc max 100 mA Door...

Страница 22: ...ility specifications This data is stored in an authorized list This list is created and edited using a keyboard 1 Differences between PRintX40AI PRintX40AV PRintX40AI Identification does not require a...

Страница 23: ...t 360gr Operating temperature 0 to 60 C 2 4 Electrical characteristics PRintX40AI_V Power supply 12Vdc 0 5A PRintX Power supply 5Vdc 1A Output relay rating 24 V 3 A Tamper sensor output TTL level max...

Страница 24: ...rews four 3 5x19mm Philips screws and four for position B four Brick Plastic anchors Mounting template User manual Recommended PRintX 40I_V Power supply adaptor 12 to 15 Vdc max 880 mA 3 Installation...

Страница 25: ...Synel Industries Ltd 25 Stand Alone Terminals Appendix A Fingerprint for PRX 40 A 3 1 Wiring...

Страница 26: ...It is recommended that quality be 50 and content 90 at least Make sure you use the enrolled finger for verification If your finger is extremely dry touch your forehead or the side of your nose before...

Отзывы: