![Synel PRX-40/A Proximity SY-11 Скачать руководство пользователя страница 15](http://html1.mh-extra.com/html/synel/prx-40-a-proximity-sy-11/prx-40-a-proximity-sy-11_product-manual_1420665015.webp)
Synel Industries Ltd.
15
Stand-Alone Terminals
Set-up mode
Time Out
After every entry a LED is lit (while waiting for the next entry). After the
LED goes out the unit exits the “Programming Mode” and resets (action must
be repeated from the beginning).
3.1.1.
Management of Access Cards (authorized personnel)
Managing access Cards can be performed three ways:
Using Keyboard - Keying-in the keyboard the card number
Using Card - Swiping the card
By Index (PRX-40/A only) - Enables inserting/deleting an employee without
a card
Using Keyboard
Build list:
After entering set-up mode key-in code 22 (key-in card number to list) (For
PRX-40/A upto 13 characters decoding or 14 characters decoding, for SY-11
card number) and key-in all relevant cards. After each keyed-in card number
2 short beeps will indicate that the number was registered successfully. After
keying-in all card numbers press 7&8 simultaneously (mandatory) (press
Enter
in terminals that consist of such a key) in order to revert to normal
mode.
Note: In operation mode 4 - card and pin code, the user must key-in the
card number and then key-in the pin code for each card (4 digit code).
Delete list:
After entering set-up mode key-in code 23 (Delete card by keyboard) and
key-in all irrelevant cards. After each keyed-in card number 2 short beeps
will indicate that the number was deleted successfully. After keying-in all
card numbers press 7&8 simultaneously (mandatory) (press
Enter
in termi-
nals that consist of such a key) in order to revert to normal mode.
Using Card
Build list:
After entering set-up mode key-in code 20 (Insert card to list by card) and
Control door
0
Opens door
Check group
17
0
1
- Disable check
- Enable check
0