Synapius ECS 20 Series Скачать руководство пользователя страница 30

New features

Fea ture

model 105TA2719 and ECS

model DC90S

ECS20xx

Max. number of users PIN codes

16

99

Master code 

programmable

programmable

Personal Unlock Code (PUC)

NO

YES

Store as user application default

NO

YES

Set user application default

NO

Reset factory settings

NO

YES

Clear user

NO

YES

Master clear

NO

YES

Reading last users

1

2

Reading emergency stops

NO

YES

Prog. emergency stop procedure

NO

YES

Automatic turn OFF

YES

YES

Programmable turn OFF time

YES

YES

Turn OFF audible beep

NO

YES

Reverse polarity input (grey wire)

NO

YES

Start inhibit

Auto turnoff time 

≠ 

0

NO

YES

Out of  operation

NO

YES

Service and maintenance mode

NO

YES

Anti-condense and ice

(Cold climate version)

NO

optional

Button touch beep

NO

YES

Operating level switches

NO

Max. 8 optional SYNAPS12/24 

Power supply

12 - 80 VDC

DIP-switch setting

12VDC Combustion engines

12-24 VDC and 24 VAC

or 48 - 90 VDC

(See ordering information)

Connections

(wires)

Power supply  + red

Power supply  - blue

Safety switch grey

-

Relay contact 2x black (make)

Power supply  + red

Power supply  - blue

Safety switch grey

Emergency stop white

Relay contact 2x black (make)

Or 1x black for combustion engines

switches internally to 12V

Electronic Code Switches

Содержание ECS 20 Series

Страница 1: ...Electronic Code Switch User and installation manual ECS 20xx series Last update January 20 2009...

Страница 2: ...Copyright TMPhysics 2006 All right reserved by Synapius BV The Netherlands Electronic Code Switches...

Страница 3: ...Electronic Code Switches...

Страница 4: ...ay 16 Programming the automatic turn off delay 16 Disabling the automatic turnoff 16 Configuring the device for access control 17 Setting the polarity of the safety switch input signal 18 Emergency st...

Страница 5: ...ompatibility with the former models 29 Mechanical 29 Electrical 29 Operation of the ECS 29 New features 30 APPENDIX A 32 Configuration list 32 CODE LIST 33 Appendix B wiring 37 Electronic Code Switche...

Страница 6: ...Electronic Code Switches...

Страница 7: ...Industrial version kgklj Electronic Code Switches...

Страница 8: ...useful during maintenance of the installation For advanced engine control it is possible to connect the ECS to the SYNAPS12 24 to control more device or switch specific operating levels This last avo...

Страница 9: ...Electrical Wide power supply versions 12 to 24 VDC or 12 24 VAC and 48 90VDC see ordering codes for powersupply ranges Power supply current is less then 60 mA Electronic Code Switches...

Страница 10: ...The ON OFF switch toggles the installation on or off by each tapping on the ON OFF button The status of the sense input of the emergency stop is shown by the red led If the installation is turned on...

Страница 11: ...nd maximum 8 digits The pincode 00000000 8 zero s is reserved for clearing an existing pincode so that this is not a valid pincode The User ID is used in the following cases Entering a new user pincod...

Страница 12: ...n which means the device is in programming mode 00 this is the location of the master code xxxxxxxx Now enter your new personal master code min 4 max 8 digits Write down this code see code list append...

Страница 13: ...on which means the device is in programming mode xx enter the location user ID number always 2 digits xxxxxxxx Now enter your new personal master code min 4 max 8 digits Write down this code see code...

Страница 14: ...ops of an individual user If the E stop handling function 2 is active re start by the user code the number of E stops are recorded for each individual user This number of E stops can be read out To do...

Страница 15: ...Electronic Code Switches...

Страница 16: ...wire can be connected through an unused contact on the accelerator Programming the automatic turn off delay Note for normal use not for access control the access control register must be set to zero T...

Страница 17: ...en 60 the this number is treated as hold time in seconds If a number greater then 60 is entered then the current number of minutes in the turnoff delay is used as hold time The grey wire is used in th...

Страница 18: ...s not zero If the ECS is turned off and the turnoff delay is not zero it is not possible to start the engine as long as the safety switch is not closed If the safety switch is a seat switch on a verhi...

Страница 19: ...start the engine The ECS provides three programmable E stop functions which will determine what to do after an emergency stop E stop E stop code 0 No action The signal will be ignored E stop code 1 Im...

Страница 20: ...as follows To clear existing keystrokes xxxxxxxx enter the master code The red LED goes on to indicate the program mode 03xx where xx are the minutes for dead time after an E stop E g if a dead time o...

Страница 21: ...you can later if nesessary restore you application settings To clear existing keystrokes xxxxxxxx enter the master code The red LED goes on to indicate the program mode 0600 Set the current configura...

Страница 22: ...e before the last user The red and green LED s will flash now the user The red flashes the ten s and the green flashes the one s Also multiplying the red flashes by ten and then adding the number of g...

Страница 23: ...porarily follow the next instructions To clear existing keystrokes xxxxxxxx enter the master code To set in program mode 3 code 3 to set out of operation Confirm To indicate that the machine is out of...

Страница 24: ...ergency signal occurs the E stop procedure mode 2 is active That means that restarting must be evoked by the master code followed by the desired E stop mode 0 1 or 2 To return to normal mode follow th...

Страница 25: ...rocedure To clear existing keystrokes xxxxxxxx Enter the PUC code Use the CE button to avoid confusion with possible user pin codes xxxxxxxx enter again the PUC code Use the CE button to avoid confusi...

Страница 26: ...9 Installation Electronic Code Switches...

Страница 27: ...ecretary For bigger loads an external relay must be used Power consumption 10mA when relay not activated and less then 60mA in activated operation Casing ABS plastic Weatherproof front side IP65 Rear...

Страница 28: ...1 Ordering Information TMP order Numbers TMP order number ECS2024 ECS2090 Notes C 40o to 60o C S 10o to 60o C P Plastic casing A Aluminium casing T surface mount F panel mount Electronic Code Switches...

Страница 29: ...itch at the back of the old model is not present any more on the new device This was one of the major source of possible problems Instead of the dip switch the code switches are separate available for...

Страница 30: ...Reverse polarity input grey wire NO YES Start inhibit Auto turnoff time 0 NO YES Out of operation NO YES Service and maintenance mode NO YES Anti condense and ice Cold climate version NO optional But...

Страница 31: ...Electronic Code Switches...

Страница 32: ...e Supplier Parameter Factory setting User application setting Master code 0000 Auto turnoff delay time 5 minutes Acces mode 0 seconds Safety sense Active low Shock detection limit 50 Emergency stop de...

Страница 33: ...ID PUC Activation code ECS serial Date of purchase Supplier User ID pincode User name Operating level 00 Master code 9 01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 Electron...

Страница 34: ...User ID pincode User name Operating level 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 Electronic Code Switches...

Страница 35: ...User ID pincode User name Operating level 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 70 71 72 73 74 Electronic Code Switches...

Страница 36: ...User ID pincode User name Operating level 75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91 92 93 94 95 96 97 98 99 Electronic Code Switches...

Страница 37: ...sis If the automatic switch off is not used leave the grey wire unconnected or to the blue wire The white wire can be connected to optional devices like Emergency switches Engine control switches e g...

Отзывы: