3
1.
In order to operate this compressor, please read and fully understand the instructions
contained in this manual before use. The compressor should only be operated by professional
personnel who fully abide by the safety instructions contained herein.
2.
Keep the compressor away from flammable materials and heat sources.
3.
Switch off the power supply and release the compressed air before each maintenance or
repair. Ensure warning stickers are displayed to avoid accidental use during this period.
4.
It is strictly prohibited to change the factory’s settings without manufacturer’s prior
written consent.
1.
The Air compressor should be placed in a clean, dry and ventilated area
2.
In order to extend the compressor lifespan, reduce the heat of moving parts by making sure the
air compressor cover is at least 0.3 - 0.5 metres away from the wall
3.
Keep the voltage within ±5% of rating
4.
Keep the oil level within the indicator
5.
Recommended compressor oil AC2100 or AC2032
6.
The normal working temperature should be -5°C - +35°C
7.
The normal working temperature of the air compressor is 180°C and the lubricating oil
in the crankcase is 70°C
8.
Open the outlet valve and let the air compressor run for 10 minutes without load before operation
www.synairgy-eu.com
Important Notice
Preparation for Usage