10
Belt Driven Compressor
Operation Manual
Model No. SACBD-100
1.
Open the drain cock under the tank and then close it.
2.
The compressor is controlled by the pressure switch. It can be stopped automatically as
pressure increases to the maximum and restarted as pressure decrease to the minimum.
The rated pressure has been set during production; do not adjust needlessly. As soon as the
motor is switched off the compressed air in the discharge pipe should be released through
the outlet valve under the switch, this is required for restarting, or the motor will be damaged.
The rated pressure can be adjusted by turning
the adjusting bolt of the switch.
3.
The outlet pressure of compressed air can be
adjusted, by the regulating valve (Fig.3). Pull up
the knob of the regulation valve and turn it
clockwise to increase the pressure.
4.
When the compressor needs to be stopped,
set the switch to the off position.
1.
Clean the crankcase and replace the lubricating oil after the first 10 working hours
2.
Check the oil level after every 20 working hours, and replenish it if necessary
3.
Open the drain cock under the tank to exhaust condensation after every 60 working hours
4.
Clean the crankcase every 120 working hours and renew the oil, clean the air filter, check the
safety valve and pressure gauge
(Fig.3)
Operation and Adjustment
Maintenance
Safety relief valve
Outlet port
Pressure gauge
Regulator