1-7-2
T7400EA
3. Operate the unit for at least 20 minutes.
4. Press "2" button on the remote control unit and
select H-Adj Mode. (Press "2" button, then display
will change H-Adj and AGC.)
5. Press CH
o
/
p
buttons on the remote control unit
so that the display will change "0" to "7."
At this moment, choose display "0" to "7" when the
Frequency counter display is closest to
15.734kHz
±
300Hz.
6. Turn the power off and on again.
2-2. C-Trap Adjustment
Purpose: To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment: If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Note: J271 (B-Out)--- Main CBA
1. Connect Oscilloscope to J271.
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-4-1.)
3. Press "0" button on the remote control unit and
select C-TRAP Mode.
4. Press "CH
o
/
p
" buttons on the remote control
unit so that the carrier leakage B-Out (3.58MHz)
value becomes minimum on the oscilloscope.
5. Turn the power off and on again.
2-3. Y DL Time/Y SW LPF
Adjustment
Purpose: To get minimum leakage of the color signal
carrier.
Symptom of Misadjustment: If Y DL Time Adjust-
ment is incorrect, stripes will appear on the screen.
1. Enter the Service Mode. (See page 1-4-1.)
2. Y DL Time Adjustment: Press "0" button on the
service remote control unit twice to show "D-T" on
the display.
Y SW LPF Adjustment: Press "0" button on the
service remote control unit four times to show
"Y SW" on the display.
3. Y DL Time Adjustment: Select "2" by pressing
"CH
o
/
p
" buttons on the service remote control
to enter Y DL Time Adjustment mode.
Y SW LPF Adjustment: Select "1" by pressing
"CH
o
/
p
" buttons on the service remote control
to enter Y SW LPF Adjustment mode.
4. If needed, perform the following.
Test point
Adj. Point
Mode
Input
J271
(B-OUT)
CH
o
/
p
buttons
---
Color Bar
Tape
M. EQ.
Spec.
---
Oscilloscope
Pattern Generator
---
Figure
minimum
Fig. 2
Y DL Time Adj TV Adjustment
CH
button
D-T TV 0
D-T TV 1
button
CH
Y DL Time Adj EXT/PB Adjustment
CH
button
D-T EXT 0
D-T EXT 1
button
CH
"0" button
Y SW LPF Adjustment
CH
button
Y SW
button
CH
"0" button
"0"
button
C-TRAP Adjustment (Factory mode)
CH
button
C-TRP 0
C-TRP 1
button
CH
"0" button
0
Y SW
1
Содержание 6319CD/EWC1903
Страница 20: ...1 6 2 T7400DC Fig 1 S 1 S 1 S 1 S 2 1 REAR CABINET ANT 1 REAR CABINET S 1 S 1 S 2 S 1 S 1 Fig 2 ...
Страница 21: ...1 6 3 T7400DC S 5 S 4 S 4 S 5 S 5 S 5 S 5 S 3 S 3 2 TRAY CHASSIS 3 DECK UNIT 4 MAIN CBA S 3 Fig 3 ...
Страница 22: ...1 6 4 T7400DC Fig 4 S 6 S 6 S 6 S 6 5 CRT CRT CBA ANODE CAP ...
Страница 72: ...2 4 8 Z12NDA Fig DM16 41 42 43 L 13 44 45 P 9 Slide Fig DM17 ...
Страница 76: ...Packing 3 1 3 T7400PEX X1 S1 S4 S15 EWC1903 only S3 S3 S2 TAPE TAPE X4 X3 X2 X7 S6 S14 FRONT ...
Страница 93: ...Printed in Japan 2003 02 17 HO 6319CD EWC1903 T7401UB 7403UD ...