F110 TIET EVENT<CR>
The XLi responds:
OK<CR><LF>
ddd:hh:mm:ss.xxxxxxxxx<CR><LF>
(Event Timing display continues until function termination with Ctrl+C)
For an IRIG Time Code with the IEEE 1344 extensions, enter F110<CR> to request the J1 Input
Configuration, and the port will respond with the ASCII character string:
F110<SP><Code><SP><Source><SP><Impedance><SP><SP><Sign><SP>
<Delay><SP><Mode><SP><Bypass><LT>
where:
F
= ASCII character F.
110
= function number.
<SP>
= ASCII space character one or more
<Code>
= Input Code: IRIG-B120 1344 or IRIG-B000 1344
<Source>
= Clock source: PRIMARY, SECONDARY, STANDBY
<Impedance>= 100K, 50 (50 ohm impedance is selectable with IRIG-B000/1344) type only)
<Sign>
= Code Sign: POSITIVE, NEGATIVE
<Delay>
= Propagation Delay: 0-99999uS
<Mode>
= IRIG Mode: SYNC GEN
<Bypass>
= Error bypass: OFF, 1 FRAME, 2 FRAMES, 3 FRAMES, 4 FRAMES, 5 FRAMES,
6 FRAMES, 7 FRAMES, 8 FRAMES, 9 FRAMES, 10 FRAMES
<LT>
= line terminator; for output strings (a carriage return and line feed ) or for input strings (a
carriage return only).
Sample request: F110<CR>
Response: F110 IRIG-B000 1344 PRIMARY 50 NEGATIVE 66161 us SYNC GEN OFF<CR><LF>
To set the J1 Input Configuration for an IRIG code with IEEE 1344 extensions, send a character string
with the previously defined F110 entry format to the Serial/Network port. Only valid values are accepted.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com