1
selecting between 10 Base-T and Auto, which provides a 100 Base-T connection where appropriate. If
you have questions about your unit, contact
H: Sales and Customer Assistance (page 295)
.
To display the current Base-T setting, enter:
F100<S>BASET<CR>
where
The XLi responds:
F100 BASET 10T<CR><LF>
To set the Ethernet port to automatically negotiate the maximum connection speed, enter:
F100<SP>BASET<SP>AUTO<Enter>
To set the Ethernet port’s connection speed to 10/100 Base-T, enter:
F100<SP>BASET<SP>10<Enter>
XLi responds:
OK <CR><LF>
RESETING THE UNIT<CR><LF>
PLEASE WAIT…<CR><LF>
F100 L/LOCK/UNLOCK – Remote Lockout
Use function F100 LOCK or UNLOCK to enable/disable TELNET access to the command line interface
through the network port. Use function F100 L to display the status of Remote Lockout. Remote Lockout
can also be set using F100 on the keypad/display interface. The factory setting is “Unlocked”. To unlock
remote lockout, use the keypad/display, the serial port command line interface.
Warning:
F100 L and F100 LOCK terminates any active TELNET sessions and prevents future
TELNET sessions. To unlock F100 L or F100 LOCK, use the serial port command line
interface or the keypad display.
To lock the unit from a remote location, enter:
F100 LOCK<CR>
F
= ASCII character F
100
= unit
function
number
<S>
= Space
BASET
= specify Base-T command
<CR>
= input
line
terminator