CHAPTER FOUR
4.10
[9] (TRANSLATOR FILTS)
U45, U43 and U41 make up the Low Pass (Envelope) Filter. The input, FILT IN source is from
[7]. The Output at pin 6 of U41 is routed through C113 to input F, of U46 at pin 15 [7].
When the Envelope Filter is turned OFF the code C from [7] is routed through amplifier U41.
Filter selection is accomplished using RSELA and RSELB of U43 and CSELA and CSELB of
U45. These filters are enabled with SR23. Filter selection is preprogrammed in ROM for the
selected input code.
A2 is a +5 Volt regulator, which provides the +5 (+5F) volts for Analog Switches U45, and U43.
U40, and U46.
U40, U30, U37, U34 and part of U23 make up the Phase Lock Loop (PLL).
T
∅
B/ is input to U37, a Phase Locked-Loop with VCO, at pin 3. U34 is setup as an integrator
whose output is inserted into the PLL IC, U37 at pin 9. The VCO output at pin 4 of U37 is routed
to the DIV 0 portion of U30. Division of DIV 0, is under program control by the Control portion
of U30. The output of DIV 0, 4CAR, is used to clock U23 which outputs TCAR90.
The Analog Switches, U40 are used to select the frequency and range of the Phase Locked Loop.
See Chapter Five, Maintenance, in this manual, for testing of the LPF (Envelope Filter) and the
Carrier Filter (PLL). Adjustments to the PLL are also found in Chapter Five.
4.11
[10] RS-232 TALKER
The RS-232 talker is used to “burst” time out periodically. U23 provides the control logic,
which is selected by switches S1-S4. U2-U5 are used to multiplex the switch selections into
U23 when the unit is powered up. U22 is a UART which formats the output data as selected,
and also generates the baud clock by dividing OSCB which comes from Y1 via U26.
4.12
[12] RS-232 I/O
This option provides for remote control and readback via RS-232. The operating program code
is contained in the basic generator and these circuits are used to provide level shift to and from
bi-polar to 5 volt logic (U53), baud rate generation, RS-232 formatting and decoding {U19), and
an interface between the relatively fast processor bus, and the slower UART (U15). Setup for
this option is provided by menus on the LCD.
4-14
TM7000 TymMachine TCG/T (Rev D)
Symmetricom, Inc.
Содержание TM7000
Страница 1: ...TM7000 TymMachine Time Code Generator Translator Revision D User s Guide 8500 0101 March 2006 ...
Страница 21: ...CHAPTER ONE This Page Intentionally Left Blank 1 14 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...
Страница 83: ...CHAPTER THREE This Page Intentionally Left Blank 3 56 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...
Страница 99: ...CHAPTER FOUR This Page Intentionally Left Blank 4 16 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...
Страница 163: ...APPENDIX A Figure One A 50 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...