OPTION DESCRIPTIONS
* * * CAUTION * * *
If the word length is set to 7 bits while using the packed BCD format, the most significant
bit of some digits will be lost and an irrational time message will be transmitted. Always
select the 8-bit word length when using the packed BCD output format.
1.5.4 STOP
BIT
There are three possible settings for the stop bit: 1, 1.5 and 2. The 1.5 setting is used for some old
teletype equipment, which does not apply here. Generally, use 1 or 2 stop bits.
1.5.5 PARITY
There are three possible settings for parity: none, odd and even. The settings are valid in both
ASCII and BCD message formats. If parity is set to odd or even, then the parity will be added to
the output word. For example, if the UART is set to 8 data bits, 1 stop bit and odd parity, then the
entire transmitted word is 11 bits in length (1 start bit + 8 data bits + 1 parity bit + 1 stop bit = 11
bits).
1.5.6 PREAMBLE
The preamble is always a hex 02 character (ASCII character STX = Start of Text). If enabled, this
will be the first byte out in either the ASCII or BCD message format.
1.5.7 POSTAMBLE
The postamble is automatically inserted into the ASCII format. It is optional in the BCD format.
The postamble comprises hex 0D, hex 10 (ASCII CR, LF) at the end of the message.
1.5.8 QUALITY
INDICATOR
The quality indicator can be enabled in either ASCII or BCD format. In the BCD format a binary
one in bit position one indicates an error in the input time code, while a binary one in bit position
one indicates a loss of the input time code signal. In the ASCII format two bytes are used for the
quality indicator (Quality 1 and Quality 2). Quality 1 byte is set to ASCII “L” (hex 4C) indicating a
loss of time code input signal. Quality 2 byte is set to ASCII “E” (hex 46) indicating an error in the
input time code. An ASCII “space” (hex 20) is set in both Quality 1 and 2 if there are no errors.
1.6 INSTALLATION
PROCEDURE
•
Disconnect the power cable from the back of the TM7000.
•
Select an open option slot and remove the two assembly securing clips from the slot rails.
•
Configure and verify the settings of the 21034 module before proceeding to the next step.
•
Insert the module into the selected option slot, being careful that the components are on the top
side of the module.
Symmetricom, Inc.
TM7000 TymMachine TCG/T (Rev D)
A-17
Содержание TM7000
Страница 1: ...TM7000 TymMachine Time Code Generator Translator Revision D User s Guide 8500 0101 March 2006 ...
Страница 21: ...CHAPTER ONE This Page Intentionally Left Blank 1 14 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...
Страница 83: ...CHAPTER THREE This Page Intentionally Left Blank 3 56 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...
Страница 99: ...CHAPTER FOUR This Page Intentionally Left Blank 4 16 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...
Страница 163: ...APPENDIX A Figure One A 50 TM7000 TymMachine TCG T Rev D Symmetricom Inc ...