6000-100Ch3.fm Rev. D
TimeVault™ User’s Manual
3-37
Web Access
Chapter 3: Remote Operation
5. Scroll down and click
MD5 Keys
.
The
NTP.Keys File
window appears, containing the following default information:
#Define your own keys and change them frequently. These keys
#must match key IDs and values assigned in your NTP client
#software setup. Note: to ensure maximum security, remember to
#change the keys on a regular basis. Key values are a maximum of
#32 characters. A maximum of 24 keys may be entered in this
#file.
#Example keys follow.
#Id M Value
#---- --- --------
1 M Symmetricom
2 M TTnts200
where 1 and 2 are key identifiers (for maximum security, use a unique combination of
32 letters and numbers for each key identifier).
6. Edit the file.
7. Click
Submit Changes
, located just below the display of parameter values.
TimeVault takes a moment to reset, during which time the parameter display goes
blank. When TimeVault starts up again, the new parameters are in place. If the unit
does not reset, check the status message to see why, re-enter the values, then click
Submit Changes
again.
If the window is empty, be sure you logged in correctly (the keys file is password protected),
then, if it is still empty, click Reload or Refresh at the top of your web browser tool bar to reload
the page.
For correct configuration, do not use zero as a key identifier. Zero means the key identification
will not be used.
Содержание Time Server
Страница 1: ...6000 100 Revision D January 2 2003 TimeVault Trusted Time Server User s Manual TM ...
Страница 7: ...6000 100Front fm Rev D TimeVault User s Manual v ...
Страница 10: ...viii TimeVault User s Manual 6000 100Front fm Rev D ...
Страница 24: ......
Страница 118: ......
Страница 138: ......
Страница 142: ......
Страница 148: ......