![Symmetricom 9611B Скачать руководство пользователя страница 26](http://html.mh-extra.com/html/symmetricom/9611b/9611b_user-manual_1419636026.webp)
Basic Operation and Features
Table 4: Auto-Switch Behavior
Autoswitch Behavior
Starting State
State Change
Primary
Input Signal
Primary
External
Fault
Secondary
Input Signal
Secondary
External
Fault
Armed
Action
Alarm
Comments
Selected and
Detected
Disabled or
Not Asserted
Detected
Disabled or
Not Asserted
Yes
None
No
This is the autoswitch's normal,
armed, starting state.
Selected and
Detected
(ignore)
Not
Detected
(ignore)
Yes
Disarm
Yes
The primary input signal is detected
but the secondary's input signal is
not detected. Disarm because auto-
switching is no longer possible.
Selected and
Detected
(ignore)
(ignore)
Enabled and
Asserted
Yes
Disarm
Yes
The primary input signal is detected
but the secondary external fault sig-
nal is enabled and asserted. Disarm
because autoswitching is no longer
possible.
Selected and
Detected
Enabled and
Asserted
Detected
Disabled or
Not Asserted
Yes
Automatically
switch
Yes
The primary input signal is detected
but the primary external fault is ena-
bled and asserted. Perform an auto-
switch due to external fault.
Selected and
Not Detected
(ignore)
Detected
Disabled or
Not Asserted
Yes
Automatically
switch
Yes
The primary input is not detected.
Perform an autoswitch due to signal
fault.
LED display after Primary signal failure
To help in understanding normal autoswitch operation, here is an example.
In the following table, the initial conditions are that Input B is the primary signal , Input A is the sec-
ondary signal and the autoswitch is armed.
Input B selected and armed
Input A
AUTO
Input B
Input A is valid
and is the sec-
ondary signal.
AUTO is armed.
Input B is valid and
selected as the primary
signal.
Input B signal fails
Input A
AUTO
Input B
Input B has been
switched to the
outputs and is
AUTO is no longer
valid. No signal is
armed.
Input B signal has failed.
Page 14
..........................................................................
9611B_UserGuide_RevA.pdf
Содержание 9611B
Страница 1: ...9611B Switching and Distribution Unit User Guide CD Number 098 00341 000 26 January 2012 i ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 14: ......
Страница 25: ...When the autoswitch is armed it behaves according to the following table 9611B_UserGuide_RevA pdf Page 13 ...
Страница 32: ......
Страница 48: ......