Basic Operation and Features
Basic Operation
The 9611B is a switched distribution unit designed to distribute RF Sine wave or either AM or digitally
modulated time codes from either one of two inputs to all twelve outputs. A typical application of the
9611B would be where a primary signal is being distributed with a secondary signal connected as a
backup in case of failure with the primary source.
The 9611B has two user interfaces: See "Front Panel Controls and Indicators " on page 21, and See
"Command Line Interface" on page 23
ModeofSwitching
The 9611B provides for both
manual
and
auto
switching.
l
Manual: In manual switching mode, selecting Input A or Input B will connect that input directly
to the twelve outputs. Input A or Input B can be selected manually by pressing the cor-
responding front panel input button, or by sending the appropriate command on the serial port
command line interface.
l
Auto: To use auto-switching mode successfully, it is first necessary to set up the conditions of
comparison. The conditions of comparison are set up over the command line interface. The
9611B allows for a voltage level, and a signal time duration comparison to be made with the
selected input signal. Once the conditions of comparison are set up, the selected input can be
"
Armed
". This can be done manually by pressing "Auto" button on the front panel, or by send-
ing the appropriate command over the command line interface. The command is that either
input signal A or signal B is to be armed.
Arming an input means that:
l
It is the primary input connected to the twelve outputs.
l
It is the input being monitored in auto-switching mode, and being compared to conditions of
comparison previously set up. If the armed input fails the comparison conditions, the auto-
switching logic switches from the Primary to the Secondary source. The alarm condition will
be indicated by both the front panel and command line interfaces.
9611B_UserGuide_RevA.pdf
..........................................................................
Page 7
Содержание 9611B
Страница 1: ...9611B Switching and Distribution Unit User Guide CD Number 098 00341 000 26 January 2012 i ...
Страница 2: ......
Страница 6: ......
Страница 12: ......
Страница 14: ......
Страница 25: ...When the autoswitch is armed it behaves according to the following table 9611B_UserGuide_RevA pdf Page 13 ...
Страница 32: ......
Страница 48: ......