SYMEO Local Positioning Radar System 

LPR-1DHP 

Product Documentation 

  

Overview Safety

 

Copyright © Symeo GmbH 2012 

 

 

Page 7 of 40 

1.5  Power Supply 

 

A safety-inspected power cable that satisfies the regulations of the 
country of use is required for the device. Devices with metal housings 
must only be connected to a grounded, shock proof socket.  

The device must not be operated unless the nominal voltage of the 
device matches the local supply voltage. Check the supply voltage of 
the device in stationary devices. 

When connecting and disconnecting wires, refer to the instructions in 
the operating instructions for the device. 

Do not use any damaged wires (damaged insulation, exposed wires). A 
faulty wire poses a risk of electric shock or fire hazard. 

Polarity reversal or otherwise faulty connection can damage the LPR-
1DHP station. In that case the station must be send to the SYMEO 
service. 

1.6  Setup and Operation 

 

During installation, make sure that no objects or fluids enter the device 
(risk of electric shock, short circuit). 

In emergencies (e. g. if there is damage to the housing, control 
elements or the mains cable, if fluids or foreign bodies have infiltrated 
the equipment), switch off the power supply to the device immediately 
and notify your SYMEO Service. 

Protect the contacts of all of the device's sockets and plugs from static 
electricity. Do not touch the contacts. If it is ever necessary to touch the 
contacts, take the following precautionary measures: Touch a grounded 
object or carry a ground strap before touching the contacts. This will 
divert static charges. 

Proper operation (in accordance with IEC60950/EN60950) of the device 
is only assured if the housing and integral covers for mounting slots are 
fully installed (electric shock, cooling, fire protection, noise suppression). 
If necessary, refer to the corresponding instructions in the operating 
instructions for the device. 

In the case of high outside temperatures and intense, direct solar 
radiation or other radiant heat, it may be necessary to provide a sun or 
heat shield. 

1.7  System Extensions and Accessories 

 

Data links to peripheral devices must be provided with adequate 
shielding. 

For LAN cabling, the requirements in accordance with EN 50173 and 
EN 50174-1/2 apply. Use of either a Category 5 shielded cable for 
10/100 Ethernet or Category 5e shielded cable for gigabit Ethernet is a 
minimum requirement. The specifications of standard ISO/IEC 11801 

Содержание LPR-1DHP

Страница 1: ...SYMEO LOCAL POSITIONING RADAR Product LPR 1DHP Product Documentation...

Страница 2: ...to User 8 2 OVERVIEW OF THE LPR 1DHP SYSTEM 9 2 1 Data sheet of LPR 1DHP Station 10 2 2 Opening angle LPR 1DHP station 10 2 3 Mounting position of the LPR 1DHP stations 11 3 COMPONENT SETUP OF THE LP...

Страница 3: ...5 Miscellaneous Area 26 7 2 6 Special Functions Area 26 7 2 7 Accept settings System Reboot 27 7 3 System Status 27 7 4 Diagnostics 29 7 5 Update Firmware 30 7 5 1 Step 1 File system 31 7 5 2 Step 2 L...

Страница 4: ...SYMEO Local Positioning Radar System LPR 1DHP Product Documentation Overview Safety Copyright Symeo GmbH 2012 Page 4 of 40...

Страница 5: ...hroughout the documentation This symbol appears before instructions that must be followed at all times Failure to comply with these instructions will result in personal injury This symbol appears befo...

Страница 6: ...n fixed tubes the necessary measures to prevent slippage of the system must be taken 1 3 Repairs Repairs of the device must be carried out by authorized technicians Unauthorized opening and incorrect...

Страница 7: ...le if fluids or foreign bodies have infiltrated the equipment switch off the power supply to the device immediately and notify your SYMEO Service Protect the contacts of all of the device s sockets an...

Страница 8: ...ded in the rear element and that the LPR 1 DHP station is completely closed Otherwise moisture can penetrate the station and damage it In order to install the LPR 1DHP station the rear element must be...

Страница 9: ...a pre configured set Unit BS1 is configured to measure with TS1 BS2 with TS2 and so on The distance values are only available on the unit labeled BS Consequently the unit BS must be mounted at the po...

Страница 10: ...ables round outside diameter 4 5 10 mm Casing dimensions LxWxH 205 x 140 x 140 mm Weight 0 9kg Hardware Interface Ethernet TCP IP or UDP USB Configuration Data interface Symeo LPR 1D protocol Antenna...

Страница 11: ...tions must be followed when available A minimum distance of 2 meters between the two system units must be maintained to guarantee the specified accuracy Minimum distance of 50 cm between adjacent syst...

Страница 12: ...A front element A3 ethernet connector version TCP IP A4 terminal for power connection A5 header for USB cable B rear element B1 alignment aid B2 ethernet connector system version TCP IP B3 cable feed...

Страница 13: ...he device as follows When the system is powered the red LED is turned on When both units are connected to the supply power and valid measurements are made the green LED is turned on or blinking with l...

Страница 14: ...HP station with TCP IP interface The rear element of the LPR 1DHP station with TCP IP interface provides the following connections see Figure 5 Ethernet connector B2 for Network connection type Hartin...

Страница 15: ...must not be removed or loosened Otherwise the housing will not be sealed in a water proof manner 4 1 1 Electrical connection Power supply is connected using the power supply terminal A4 Ethernet is co...

Страница 16: ...power supply terminal A4 USB is connected using terminal B6 Figure 7 depicts the pin assignment of A5 The pin assignment of A4 is similar to A4 as described in section 4 1 1 Polarity reversal or othe...

Страница 17: ...rt the Ethernet connector B5 of the rear element B into the connector A3 of front element A Mount the front element A on the rear element B It might be necessary to tighten the inserted power cable Fi...

Страница 18: ...nnection to LPR 1DHP Station With delivery the LPR 1DHP stations have the fixed IP Address 192 168 1 99 if no other IP Address is labeled outside the LPR 1DHP station You can change the IP Address of...

Страница 19: ...this case deactivate the firewall temporarely under the tab Advanced The LPR Station should be available via your PC now You can check the connection with a ping to the LPR 1DHP station Open the Comma...

Страница 20: ...een configured for this see section Settings HTTP and HTTPS fields in the Remote Access area In HTTP connections the data is transmitted unencrypted In HTTPS connections it is encrypted for transmissi...

Страница 21: ...zed personnel see section Remote Access Area table row Password from page 25 7 2 Settings With this function you can define the network settings on your LPR 1DHP station define the network access sett...

Страница 22: ...time zone see chapter 7 2 5 Special Functions See chapter 7 2 6 Press button Upload changes to accept the changes of the LPR 1DHP station Press button Reboot System to reboot the LPR 1DHP station wit...

Страница 23: ...tandard gateway default 192 168 98 254 Other LAN segments can be reached with the standard gateway In DHCP Active mode this address is assigned by the server and cannot be edited 7 2 2 Network Area Ho...

Страница 24: ...7 2 3 2 ttyS3 Binary Port Network Settings Area IP Server For all active connection types the IP address of the server is required to which the connection should be established Data Port Port Number o...

Страница 25: ...nge the reverse channel autonomously If the connection is opened successful you get access to the binary port Fixed Frame means deactivated Byte Stuffing fixed protocol length UDP Fixed Frame Sending...

Страница 26: ...chnical department The enormous range of functions that are available to console access means that only some can be documented here To find out more please contact your IT administrator or Symeo Suppo...

Страница 27: ...Download Settings to download a copy of the configuration as a backup 7 2 7 Accept settings System Reboot As described in chapter 7 2 it is necessary to transmit the changes to the LPR 1DHP station a...

Страница 28: ...of reserved bits and the kernel code MemFree Free working memory Filesystem Details about the active file systems and associated statistics OS Version Operating system kernel compiler and compiling da...

Страница 29: ...lue grater zero means problems when receiving or sending data This happens if the data cannot be readout fast enough Example 1 waiting for incoming connection Proto Recv Q Send Q Local Address Foreign...

Страница 30: ...date Firmware With this function you can update the firmware The firmware can be updated for example when a firmware with improved functional scope is available for the LPR system The system can also...

Страница 31: ...ible to make a copy of the actual firmware by downloading the firmware from the LPR 1DHP station Click the button Backup ramdisk gz Click the Browse button in the Step 1 flash ramdisk gz area A file b...

Страница 32: ...file to the non volatile memory Transfer progress is displayed in a message window You will know when this operation is complete because a message done file ramdisk gz removed will be output and a li...

Страница 33: ...IP interface Copyright Symeo GmbH 2012 Page 33 of 40 Click the Browse button in the Step 2 flash zImage area A file browser window will open Navigate to the file you want and click Open Click the Uplo...

Страница 34: ...34 of 40 Click the Execute button in the Step 2 flash zImage area to transfer the file to the non volatile memory Transfer progress is displayed in a message window You will know when this operation...

Страница 35: ...ware contains additional configuration files the settings you made are set to factory settings This applies also for the IP address which is set to the default value 192 168 1 99 Symeo recommends rest...

Страница 36: ...h TCP IP interface Copyright Symeo GmbH 2012 Page 36 of 40 Click System Log in the navigation bar If you have not yet provided authentication information you will be prompted to do so now see chapter...

Страница 37: ...yte 1 byte 1 byte CRC 2 byte END 0x7f Figure 1 Structure of data the packet The START and the STOP field is in each data packet the reserved symbol 0x7e and 0x7f TYPE indicates the type of the data pa...

Страница 38: ...priate calculation for coding must applied before byte stuffing If receiving the data from the LPR 1DHP system the byte stuffing must be resolved to get the original symbol Then the CRC is updated wit...

Страница 39: ...P IP Fixed Frame Protocol If the LPR 1DHP station has a TCP IP interface two options are available for the protocol Either you use the protocol as it is sent from the serial interface with different d...

Страница 40: ...DP port of the PC has to be configured in the LPR protocol inverter The converter sends each data packet as a UDP packet of a fixed length 89 byte to the PC Compared to the TCP fixed frame option the...

Отзывы: