SYMEO Local Positioning Radar System
LPR-1DHP
Product Documentation
Commissioning LPR-1DHP with TCP/IP interface
Copyright © Symeo GmbH 2012
Page 18 of 40
6
Commissioning LPR-1DHP with TCP/IP interface
6.1
Requirements
In order for a station to be successfully commissioned, the LPR-1DHP components must
have been installed correctly:
The station has been installed.
The station has been connected to the power supply.
Data link has been established over TCP/IP.
Once these prerequisites have been fulfilled, you can connect the station to the network and
commission the LPR-1DHP system. How to do this is explained in the following chapters.
6.2
Connection to LPR-1DHP Station
With delivery the LPR-1DHP stations have the fixed IP-Address
192.168.1.99
, if no other IP-Address is labeled outside the LPR-1DHP
station.
You can change the IP-Address of the LPR-1DHP station via the web
interface of the LPR-Station.
To get a connection between your PC and the LPR-1DHP station it is
maybe neccessary to change the network parameters of your computer.
Both units must be loctaed in the same network. That means in this
example that the first three numeric pads of both IP-addresses must be
the same.
Disconnect your PC from the network. Connect the LPR-1DHP station and the computer with
a network cable. Open your network settings of your computer.
Figure 8
– Network Settings
Enter the following fixed IP-
Address i.e.
192.168.1.1
.
The subnet mask should be
set to
255.255.255.0
.
Click in both windows
OK
.