background image

SYMEO Local Positioning Radar System 

LPR®-1D24 

LPR®-1D24 Station 

– Overview and Mounting 

 

 

Overview of LPR®-1D24 Unit 

Copyright © SYMEO GmbH 2015 

 

LPR-1D24_Users_Manual_FCC-IC-Edition_EN.docx 

Page 8 of 34 

Overview of LPR

®

-1D24 Unit 

LPR

®

-1D24  is  a  highly  precise  radio  sensor  for  distance  measurement.  Two  paired  units 

allow for  long range applications and enable additional data transfer  at the same time. The 
exact  position  of  a  moving  machine  component,  e.g.  a  crane  or  crane  trolley,  can  thus  be 
dynamically determined in real-time, while data collected at one end (e.g. a load cell input) is 
available at the paired unit simultaneously. 

 

Distance measurement and user data 

transmission

LPR

®

-1D24

 

Figure 1: LPR

®

-1D24 measurement path 

 

In  addition  to  the  distance  reading,  the  relative  approach  speed  of  the  LPR

®

  sensors  is 

available.  Distance  and  speed  can  be  used  for  internal  collision  avoidance  decisions  at 
predetermined  distance  thresholds.  Optional  on-board  relays  will  be  activated.  All  data  is 
made available at standard interfaces. 

The  devices  are  easy  to  install  and  operate.  Rough  alignment  between  the  facing  units  is 
sufficient, even for very long distances. The multi-channel radio antenna is integrated into the 
robust  housing. A built-in terminal server  allows  straightforward  configuration of the unit ID, 
the paired unit ID and other parameters in any browser.  

Symeo LPR

®

 radio works highly reliable under adverse conditions. Interference with any WiFi 

equipment operating in parallel can be excluded at all times. A unique ID per each unit allows 
operating multiple pairs in immediate vicinity. 

LPR

®

-1D24  sensors  are  maintenance-free  and  paired  sensors  can  be  interconnected  with 

other  pairs,  providing  several  distances  at  a  single  interface,  e.g.  for  crane  xy  position 
acquired by two sensor pairs. 

 

 

Содержание BSV101757

Страница 1: ...opyright SYMEO GmbH 2009 Date August 2009 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 1 of 34 SYMEO LOCAL POSITIONING RADAR Product LPR 1D24 Symeo BSV101757 Product Documentation Table of Conten...

Страница 2: ...ns and Accessories 7 1 8 Additional Instructions 7 1 9 General Requirements for Compliance of Radio Apparatus 7 2 OVERVIEW OF LPR 1D24 UNIT 8 2 1 Technical Data LPR 1D24 Unit 9 3 MOUNTING AND ALIGNMEN...

Страница 3: ...Unit 18 7 2 Open User Interface 20 7 3 Device 22 7 4 Device Device Configuration 23 7 4 1 Device Device Configuration LAN 24 7 4 2 Device Device Configuration System Time 26 7 5 Device Application Set...

Страница 4: ...e 12 Device Menu 22 Figure 13 Information overview and device status 22 Figure 14 Device Device Configuration Menu 23 Figure 15 Device Device Configuration LAN Settings 24 Figure 16 Device Device Conf...

Страница 5: ...e following symbols are used throughout the documentation This symbol appears before instructions that must be followed at all times Failure to comply with these instructions will result in personal i...

Страница 6: ...ed This ensures protection from crushing impact moisture and electrostatic discharge During setup and before operation refer to the instructions for environmental conditions in this document and in th...

Страница 7: ...PR 1D24 unit must not be opened 1 7 System Extensions and Accessories Data cables to peripheral devices must be shielded properly For LAN cabling the requirements apply in accordance with EN 50173 and...

Страница 8: ...sensors is available Distance and speed can be used for internal collision avoidance decisions at predetermined distance thresholds Optional on board relays will be activated All data is made availabl...

Страница 9: ...1D24 Unit Copyright SYMEO GmbH 2015 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 9 of 34 2 1 Technical Data LPR 1D24 Unit The technical specifications for LPR 1D24 can be found in our data sheet...

Страница 10: ...unt the LPR 1D24 unit to a suitable pipe with the bracket To adjust the system do not tighten the mounting bracket finally Specified alignments have to be adhered to if indicated by Symeo A minimum di...

Страница 11: ...following components A 2 x ring nuts M5 B 2 x snap hooks 5 x 50 mm C 1 x steel cable 3 mm x 1 m The two ring nuts must be mounted on the back of the LPR 1D24 unit laterally on the respective second s...

Страница 12: ...5 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 12 of 34 4 Requirements for Power Supply The power supply should have the following characteristics Potential free Output power at least 25 W Output...

Страница 13: ...nnections in detail B1 B2 B5 B7 B6 B4 B3 B9 B1 B2 B5 B7 B6 B4 B3 B11 B10 B9 B8 Figure 4 LPR 1D24 Connectors B1 Ethernet B2 Can Bus IN Profibus IN B3 Can Bus OUT Profibus OUT Termination optional B4 Pr...

Страница 14: ...or to the operating voltage Figure 4 Connection B6 5 2 1 Plugs Recommended connector o SACC M12FST 4PECON PG 9 M 1418052 Cable diameter 6 8 mm Symeo order number MTE101761 Figure 5 M12 Connector for t...

Страница 15: ...12 5 3 2 Pin Assignment Table 6 Pin assignment for Ethernet M12 5 3 3 Connector Cable M12 RJ45 The connector cable M12 RJ45 is required for the Ethernet connection for configuration of the LPR 1D24 un...

Страница 16: ...age 16 of 34 5 4 1 Plugs Recommended connector Connector SCPU 10 G 02 00 MBS AM from Samtec USB mini B plug Pin assignment according to USB Standard If the USB port at the device is not used it must b...

Страница 17: ...view and Mounting LPR 1D24 Housing Dimensions Copyright SYMEO GmbH 2015 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 17 of 34 6 LPR 1D24 Housing Dimensions Figure 7 LPR 1D24 Housing Dimensions Th...

Страница 18: ...has been established over TCP IP Once these prerequisites have been fulfilled you can connect the unit to the network and commission the LPR 1D24 system How to do this is explained in the following ch...

Страница 19: ...Click in both windows OK If the firewall settings are too restrictive you may not get access to the LPR 1D24 unit In this case deactivate the firewall temporarily The LPR unit should be available via...

Страница 20: ...box Open your web browser In the address bar of the web browser enter the IP address of the LPR 1D24 unit http 192 168 1 99 Press Enter A connection is established with your LPR 1D24 unit Figure 10 Ho...

Страница 21: ..._Users_Manual_FCC IC Edition_EN docx Page 21 of 34 Enter the user name symeo and the password 54all2u and press Login Now your status is displayed as Logged in Figure 11 Sign in on the home page of th...

Страница 22: ...picture below Figure 13 Information overview and device status The information overview shows you the Hostname of the LPR 1D24 unit and its IP address The device status shows you the status of the ser...

Страница 23: ...LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 23 of 34 7 4 Device Device Configuration With this function see picture below you can chose either to define the LAN settings define Modem settings d...

Страница 24: ...vice Device Configuration LAN With this function see picture below you can chose the Link type define the Address Mode change the IP Address change the IP Netmask change the Gateway change the local H...

Страница 25: ...een saved in the picture below the hostname Now you need to press Commit if you want to apply the change The unit will perform a reboot to apply it If you want to discard the change press Reset Figure...

Страница 26: ...h this function see picture below you chose to set the time zone o must be set to custom timezone if needed timezone is not in the dropdown menu set the IP address of the NTP server set the Custom tim...

Страница 27: ...e picture below you chose to set the Protocol frame length set the Protocol TCP port define the Output interval of customer protocol Figure 20 Device Application Settings Costumer Protocol Settings 7...

Страница 28: ...n channel number Has to be the same on all units needing to communicate with each other o The lowest usable communication channel is channel 16 the highest usable channel is channel 95 depending on th...

Страница 29: ...IC Edition_EN docx Page 29 of 34 Figure 22 Example configuration of one measurement pair Master and Slave Unit Configuration rules Don t use a group ID more than once per site If pairs of LPR units a...

Страница 30: ...1D24 Copyright SYMEO GmbH 2015 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 30 of 34 7 6 Diagnostics With this function see picture below you chose to Operating System Status Hardware Status Reco...

Страница 31: ...Copyright SYMEO GmbH 2015 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 31 of 34 7 6 1 Diagnostics Operating System Status With this function see picture below the operating system status can be s...

Страница 32: ...5 LPR 1D24_Users_Manual_FCC IC Edition_EN docx Page 32 of 34 7 6 2 Diagnostics Hardware Status With this function see picture below system values and system voltages are displayed In case of problems...

Страница 33: ...Edition_EN docx Page 33 of 34 7 6 3 Diagnostics Distance over Time With this function see picture below the current distance and the current RSSI value Signal strength will be displayed Furthermore t...

Страница 34: ...ys the distance between the two LPR 1D24 stations and the RSSI axis the received signal strength in dB As the signal strength at specific distances may vary the statistical distribution of the signal...

Отзывы: