5-75
Parameter Menus
Set Lengths for MSI Plessey
Parameter # L1 = 0x1E, L2 = 0x1F
Lengths for MSI Plessey may be set for any length, one or two discrete lengths, or lengths
within a specific range. The length of a code refers to the number of characters (i.e., human
readable characters) the code contains, and includes check digits. See Table B-5 on page B-7
for ASCII equivalents. To set lengths via serial commands, see
Setting Code Lengths Via Serial
One Discrete Length
- This option allows you to decode only those codes containing a
selected length. For example, if you select
MSI Plessey One Discrete Length
, then scan
1
,
4
,
the only MSI Plessey symbols decoded are those containing 14 characters. Numeric bar codes
begin on page 5-102. If you make an error, or wish to change your selection, scan the
bar code on page 5-104.
MSI Plessey - ONE DISCRETE LENGTH
Two Discrete Lengths
- This option allows you to decode only those codes containing two
selected lengths. For example, if you select
MSI Plessey Two Discrete Lengths
, then scan
0
,
2
,
1
,
4
, the only MSI Plessey symbols decoded are those containing 2 or 14 characters. Numeric
bar codes begin on page 5-102. If you make an error, or wish to change your selection,
scan the
bar code on page 5-104.
MSI Plessey - TWO DISCRETE LENGTHS
Содержание SE 923
Страница 1: ...SE 923 Scan Engine Integration Guide...
Страница 2: ...2 70 37052 01 Rev A February 1999 Symbol Technologies Inc One Symbol Plaza Holtsville N Y 11742 1300...
Страница 3: ...SE 923 Scan Engine Integration Guide 70 37052 01 Rev A February 1999...
Страница 10: ...viii SE 923 Scan Engine Integration Guide...
Страница 16: ...xiv SE 923 Scan Engine Integration Guide...
Страница 22: ...1 6 SE 923 Scan Engine Integration Guide...
Страница 29: ...2 7 Installation Figure 2 3 Exit Window Positioning CASE 1 CASE 2...
Страница 52: ...4 8 SE 923 Scan Engine Integration Guide...
Страница 135: ...5 83 Parameter Menus Prefix Suffix Values DATA FORMAT CANCEL...
Страница 138: ...5 86 SE 923 Scan Engine Integration Guide Scan Data Transmission Format PREFIX DATA SUFFIX 1 SUFFIX 2 0x07...
Страница 155: ...5 103 Parameter Menus Numeric Bar Codes cont d 4 5 6 7...
Страница 196: ...6 40 SE 923 Scan Engine Integration Guide...
Страница 232: ...Glossary 8 SE 923 Scan Engine Integration Guide...
Страница 236: ...Index 4 SE 923 Scan Engine Integration Guide...
Страница 238: ......